ΠŸΠΎΠΌΠΎΡ‰ΡŒ Π² ΡƒΡ‡Ρ‘Π±Π΅, ΠΎΡ‡Π΅Π½ΡŒ быстро...
Π Π°Π±ΠΎΡ‚Π°Π΅ΠΌ вмСстС Π΄ΠΎ ΠΏΠΎΠ±Π΅Π΄Ρ‹

Π Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠ² совмСщСния Π»ΡƒΡ‡Π΅Π²Ρ‹Ρ… ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ ΠΈ ΠΈΡ… примСнСния Π² ΠΊΠ»ΠΈΠ½ΠΈΠΊΠ΅

Π”ΠΈΡΡΠ΅Ρ€Ρ‚Π°Ρ†ΠΈΡΠŸΠΎΠΌΠΎΡ‰ΡŒ Π² Π½Π°ΠΏΠΈΡΠ°Π½ΠΈΠΈΠ£Π·Π½Π°Ρ‚ΡŒ ΡΡ‚ΠΎΠΈΠΌΠΎΡΡ‚ΡŒΠΌΠΎΠ΅ΠΉ Ρ€Π°Π±ΠΎΡ‚Ρ‹

ΠŸΡ€Π°ΠΊΡ‚ΠΈΡ‡Π΅ΡΠΊΠ°Ρ Π·Π½Π°Ρ‡ΠΈΠΌΠΎΡΡ‚ΡŒ Ρ€Π°Π±ΠΎΡ‚Ρ‹. ΠŸΡ€Π°ΠΊΡ‚ΠΈΡ‡Π΅ΡΠΊΠ°Ρ Π·Π½Π°Ρ‡ΠΈΠΌΠΎΡΡ‚ΡŒ Ρ€Π°Π±ΠΎΡ‚Ρ‹ Π·Π°ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ΡΡ Π² ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ простотС ΠΏΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½Π½ΠΎΠ³ΠΎ ΠΌΠ΅Ρ‚ΠΎΠ΄Π° совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ, Π½Π΅ Ρ‚Ρ€Π΅Π±ΡƒΡŽΡ‰Π΅Π³ΠΎ использования слоТного ΠΏΡ€ΠΎΠ³Ρ€Π°ΠΌΠΌΠ½ΠΎΠ³ΠΎ ΠΈ Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠ³ΠΎ тСхничСского обСспСчСния. Π‘ΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠ² Π²ΠΈΠ·ΡƒΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ (МРВ, МБКВ, ПЭВ) Π΄Π°Π΅Ρ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ ΠΎΠ΄Π½ΠΎΠ²Ρ€Π΅ΠΌΠ΅Π½Π½ΠΎ ΠΏΠΎΠ»ΡƒΡ‡ΠΈΡ‚ΡŒ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡŽ… Π§ΠΈΡ‚Π°Ρ‚ΡŒ Π΅Ρ‰Ρ‘ >

Π‘ΠΎΠ΄Π΅Ρ€ΠΆΠ°Π½ΠΈΠ΅

  • Бписок сокращСний
  • ГЛАВА 1. ΠžΠ‘Π—ΠžΠ  Π›Π˜Π’Π•Π ΠΠ’Π£Π Π«
    • 1. 1. ΠœΠ΅Ρ‚ΠΎΠ΄ΠΎΠ»ΠΎΠ³ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ аспСкты совмСщСния 9 ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ
    • 1. 2. Π‘ΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… Π»ΡƒΡ‡Π΅Π²Ρ‹Ρ… 17 ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… анатомичСских областСй Π² ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅
  • ГЛАВА 2. ΠžΠ‘Π©ΠΠ― Π₯ΠΠ ΠΠšΠ’Π•Π Π˜Π‘Π’Π˜ΠšΠ ΠœΠΠ’Π•Π Π˜ΠΠ›Π И 26 ΠœΠ•Π’ΠžΠ”Π« Π˜Π‘Π‘Π›Π•Π”ΠžΠ’ΠΠΠ˜Π―
    • 2. 1. Π­ΠΊΡΠΏΠ΅Ρ€ΠΈΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½Ρ‹Π΅ исслСдования
    • 2. 2. ΠœΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ исслСдования
    • 2. 3. ИсслСдованиС ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² с ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ 41 стСрСотаксичСского Π°Π΄Π°ΠΏΡ‚Π΅Ρ€Π°
    • 2. 4. ΠœΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° совмСщСния ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… 42 анатомичСских областСй
    • 2. 5. БтатистичСский Π°Π½Π°Π»ΠΈΠ· Π΄Π°Π½Π½Ρ‹Ρ…
  • ГЛАВА 3. РЕЗУЛЬВАВЫ Π­ΠšΠ‘ΠŸΠ•Π Π˜ΠœΠ•ΠΠ’ΠΠ›Π¬ΠΠ«Π₯ Π˜Π‘Π‘Π›Π•Π”ΠžΠ’ΠΠΠ˜Π™
  • ГЛАВА 4. РЕЗУЛЬВАВЫ ΠšΠ›Π˜ΠΠ˜Π§Π•Π‘ΠšΠ˜Π₯ Π˜Π‘Π‘Π›Π•Π”ΠžΠ’ΠΠΠ˜Π™
    • 4. 1. ИсслСдования Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° с ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ 62 стСрСотаксичСского Π°Π΄Π°ΠΏΡ‚Π΅Ρ€Π°
    • 4. 2. ИсслСдования Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° Π±Π΅Π· примСнСния 69 стСрСотаксичСского Π°Π΄Π°ΠΏΡ‚Π΅Ρ€Π°
    • 4. 3. Π‘ΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ ΠΎΡ€Π³Π°Π½ΠΎΠ² Π³Ρ€ΡƒΠ΄Π½ΠΎΠΉ полости
    • 4. 4. Π‘ΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ 83 Π±Ρ€ΡŽΡˆΠ½ΠΎΠΉ полости ΠΈ Π·Π°Π±Ρ€ΡŽΡˆΠΈΠ½Π½ΠΎΠ³ΠΎ пространства
    • 4. 5. Π‘ΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ 90 области ΠΌΠ°Π»ΠΎΠ³ΠΎ Ρ‚Π°Π·Π°

Π Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠ² совмСщСния Π»ΡƒΡ‡Π΅Π²Ρ‹Ρ… ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ ΠΈ ΠΈΡ… примСнСния Π² ΠΊΠ»ΠΈΠ½ΠΈΠΊΠ΅ (Ρ€Π΅Ρ„Π΅Ρ€Π°Ρ‚, курсовая, Π΄ΠΈΠΏΠ»ΠΎΠΌ, ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Π°Ρ)

ΠΠΊΡ‚ΡƒΠ°Π»ΡŒΠ½ΠΎΡΡ‚ΡŒ ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌΡ‹. ΠŸΠΎΠ²Ρ‹ΡˆΠ΅Π½ΠΈΠ΅ эффСктивности диагностики онкологичСских ΠΈ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Π½Π΅ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅Π²Ρ‹Ρ… Π·Π°Π±ΠΎΠ»Π΅Π²Π°Π½ΠΈΠΉ являСтся ΠΎΠ΄Π½ΠΎΠΉ ΠΈΠ· Π½Π°ΠΈΠ±ΠΎΠ»Π΅Π΅ Π°ΠΊΡ‚ΡƒΠ°Π»ΡŒΠ½Ρ‹Ρ… Π·Π°Π΄Π°Ρ‡ соврСмСнной ΠΊΠ»ΠΈΠ½ΠΈΠΊΠΈ. Π’Π½Π΅Π΄Ρ€Π΅Π½ΠΈΠ΅ Π² ΠΌΠ΅Π΄ΠΈΡ†ΠΈΠ½ΡΠΊΡƒΡŽ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΡƒ ΠΌΠ°Π³Π½ΠΈΡ‚Π½ΠΎ-рСзонансной, ΡΠΏΠΈΡ€Π°Π»ΡŒΠ½ΠΎΠΉ ΠΊΠΎΠΌΠΏΡŒΡŽΡ‚Π΅Ρ€Π½ΠΎΠΉ Ρ‚ΠΎΠΌΠΎΠ³Ρ€Π°Ρ„ΠΈΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ соврСмСнных ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠ² ядСрной ΠΌΠ΅Π΄ΠΈΡ†ΠΈΠ½Ρ‹, ΠΏΡ€Π΅ΠΆΠ΄Π΅ всСго ΠΏΠΎΠ·ΠΈΡ‚Ρ€ΠΎΠ½Π½ΠΎΠΉ эмиссионной Ρ‚ΠΎΠΌΠΎΠ³Ρ€Π°Ρ„ΠΈΠΈ, ΠΏΠΎΠ·Π²ΠΎΠ»ΠΈΠ»ΠΎ Π² Π·Π½Π°Ρ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ стСпСни ΠΏΠΎΠ²Ρ‹ΡΠΈΡ‚ΡŒ ΡΡ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ Π»ΡƒΡ‡Π΅Π²ΠΎΠΉ диагностики ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅ΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½ΠΎΠΉ Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ. Однако ΠΌΠ½ΠΎΠ³ΠΈΠ΅ вопросы, ΠΊΠ°ΡΠ°ΡŽΡ‰ΠΈΠ΅ΡΡ Π΄ΠΈΡ„Ρ„Π΅Ρ€Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½ΠΎΠΉ диагностики ΠΈ Ρ‚ΠΎΡ‡Π½ΠΎΠΉ Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ выявлСнных ΠΈΠ·ΠΌΠ΅Π½Π΅Π½ΠΈΠΉ, ΠΎΡΡ‚Π°ΡŽΡ‚ΡΡ Π½Π΅Ρ€Π΅ΡˆΠ΅Π½Π½Ρ‹ΠΌΠΈ. Π­Ρ‚ΠΎ, Π³Π»Π°Π²Π½Ρ‹ΠΌ ΠΎΠ±Ρ€Π°Π·ΠΎΠΌ, связано с ΠΌΠ½ΠΎΠ³ΠΎΠΎΠ±Ρ€Π°Π·ΠΈΠ΅ΠΌ Π»ΡƒΡ‡Π΅Π²ΠΎΠΉ сСмиотики ΠΈ ΡΠ»ΠΎΠΆΠ½ΠΎΡΡ‚ΡŒΡŽ ΠΎΠ΄Π½ΠΎΠ·Π½Π°Ρ‡Π½ΠΎΠΉ ΠΈΠ½Ρ‚Π΅Ρ€ΠΏΡ€Π΅Ρ‚Π°Ρ†ΠΈΠΈ Π΄Π°Π½Π½Ρ‹Ρ… МРВ ΠΈ ΠšΠ’, ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ°ΡŽΡ‰ΠΈΡ…, прСимущСствСнно, структурныС измСнСния Π² Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΎΡ€Π³Π°Π½Π°Ρ…. ΠŸΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊ ядСрной ΠΌΠ΅Π΄ΠΈΡ†ΠΈΠ½Ρ‹, Π² Ρ‡Π°ΡΡ‚ности ПЭВ ΠΈ ΠžΠ€Π­ΠšΠ’, Π΄Π°Π΅Ρ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ ΠΎΡ†Π΅Π½ΠΈΡ‚ΡŒ Π½Π° ΠΊΠ»Π΅Ρ‚ΠΎΡ‡Π½ΠΎΠΌ ΡƒΡ€ΠΎΠ²Π½Π΅ мСтаболичСскиС процСссы Π² ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅Π²ΠΎΠΉ Ρ‚ΠΊΠ°Π½ΠΈ. ИспользованиС соврСмСнных РЀП позволяСт Π² Π·Π½Π°Ρ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ стСпСни ΡƒΠ²Π΅Π»ΠΈΡ‡ΠΈΡ‚ΡŒ ΡΠΏΠ΅Ρ†ΠΈΡ„ΠΈΡ‡Π½ΠΎΡΡ‚ΡŒ ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΠΌΠΎΠ³ΠΎ исслСдования. Однако ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹ ядСрной Π²ΠΈΠ·ΡƒΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ ΠΈΠΌΠ΅ΡŽΡ‚ ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ Π½ΠΈΠ·ΠΊΠΎΠ΅ пространствСнноС Ρ€Π°Π·Ρ€Π΅ΡˆΠ΅Π½ΠΈΠ΅. ΠŸΠΎΡΡ‚ΠΎΠΌΡƒ Π½Π΅Ρ€Π΅Π΄ΠΊΠΎ ΠΏΡ€ΠΈ Π°Π½Π°Π»ΠΈΠ·Π΅ Π΄Π°Π½Π½Ρ‹Ρ… ПЭВ ΠΈ ΠžΠ€Π­ΠšΠ’ Π²ΠΎΠ·Π½ΠΈΠΊΠ°ΡŽΡ‚ слоТности с Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠ΅ΠΉ ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠ΅Π½Π½Ρ‹Ρ… патологичСских ΠΈΠ·ΠΌΠ΅Π½Π΅Π½ΠΈΠΉ. Π­Ρ‚Ρƒ ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌΡƒ, Π² Π±ΠΎΠ»ΡŒΡˆΠΈΠ½ΡΡ‚Π²Π΅ случаСв, позволяСт Ρ€Π΅ΡˆΠΈΡ‚ΡŒ совмСщСниС ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ, ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½Ρ‹Ρ… с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠ², Π²Ρ‹ΡΠ²Π»ΡΡŽΡ‰ΠΈΡ… структурныС (MPT, КВ) ΠΈ Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹Π΅ (ОЀЭКВ, ПЭВ) измСнСния. Π’ Π½Π°ΡΡ‚оящСС врСмя данная тСхнология ΡƒΡΠΏΠ΅ΡˆΠ½ΠΎ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅Ρ‚ΡΡ для Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ ΠΎΡ‡Π°Π³Π° пораТСния, Π² Ρ‡Π°ΡΡ‚ности, ΠΏΡ€ΠΈ ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠΈ стСрСотаксичСских Π²ΠΌΠ΅ΡˆΠ°Ρ‚Π΅Π»ΡŒΡΡ‚Π² Ρƒ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² с ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅Π²Ρ‹ΠΌΠΈ ΠΈ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΌΠΈ Π½Π΅ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅Π²Ρ‹ΠΌΠΈ заболСваниями Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° [Petrzyk U. et al., 1996, Julow J. et al., 2000, Grosu A.L. et al., 2003]. Π’ Ρ‚ΠΎΠΆΠ΅ врСмя ΡˆΠΈΡ€ΠΎΠΊΠΎΠ΅ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ совмСщСния ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Π² ΠΎΠ½ΠΊΠΎΠ»ΠΎΠ³ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΊΠ»ΠΈΠ½ΠΈΠΊΠ΅ ΠΎΠ³Ρ€Π°Π½ΠΈΡ‡Π΅Π½ΠΎ Π² ΡΠ²ΡΠ·ΠΈ с ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌΠ°ΠΌΠΈ тСхничСского ΠΈ ΠΌΠ΅Ρ‚одологичСского Ρ…Π°Ρ€Π°ΠΊΡ‚Π΅Ρ€Π°. Π‘ΠΎΠ»ΡŒΡˆΠΈΠ½ΡΡ‚Π²ΠΎ Ρ€Π°Π±ΠΎΡ‚, посвящСнных использованию Π΄Π°Π½Π½ΠΎΠΉ Ρ‚Π΅Ρ…Π½ΠΎΠ»ΠΎΠ³ΠΈΠΈ для диагностики ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅Π²Ρ‹Ρ… Π·Π°Π±ΠΎΠ»Π΅Π²Π°Π½ΠΈΠΉ Π³Ρ€ΡƒΠ΄Π½ΠΎΠΉ, Π±Ρ€ΡŽΡˆΠ½ΠΎΠΉ полостСй, ΠΌΠ°Π»ΠΎΠ³ΠΎ Ρ‚Π°Π·Π°, Π²Ρ‹ΠΏΠΎΠ»Π½Π΅Π½Ρ‹ Π½Π° ΡΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½Π½Ρ‹Ρ… КВ/ПЭВ томографичСских установках, выпускаСмых Π²Π΅Π΄ΡƒΡ‰ΠΈΠΌΠΈ Ρ„ΠΈΡ€ΠΌΠ°ΠΌΠΈ-производитСлями мСдицинской Ρ‚Π΅Ρ…Π½ΠΈΠΊΠΈ [Patton J.A. et al., 2000, Townsend D.W. et al., 2001, Beyer T et al., 2001;2003]. Π­Ρ‚ΠΈ исслСдования ΡΠ²ΠΈΠ΄Π΅Ρ‚Π΅Π»ΡŒΡΡ‚Π²ΡƒΡŽΡ‚ ΠΎ Π²Ρ‹ΡΠΎΠΊΠΎΠΉ эффСктивности совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ для диагностики ΠΈ Π΄ΠΈΡ„Ρ„Π΅Ρ€Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½ΠΎΠΉ диагностики ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅ΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½ΠΎΠΉ Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ Π² Ρ‚Π΅Ρ… случаях, ΠΊΠΎΠ³Π΄Π° Π°Π½Π°Π»ΠΈΠ· ΠΈΠ·ΠΎΠ»ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹Ρ… КВ, МРВ ΠΈ ΠŸΠ­Π’ Π΄Π°Π½Π½Ρ‹Ρ… ΠΏΡ€ΠΈΠ²ΠΎΠ΄ΠΈΡ‚ ΠΊ ΡΠΎΠΌΠ½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΌ, Π² Ρ‚ΠΎΠΌ числС ΠΊ Π»ΠΎΠΆΠ½ΠΎΠΎΡ‚Ρ€ΠΈΡ†Π°Ρ‚Π΅Π»ΡŒΠ½Ρ‹ΠΌ ΠΈΠ»ΠΈ Π»ΠΎΠΆΠ½ΠΎΠΏΠΎΠ»ΠΎΠΆΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΌ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π°ΠΌ. Однако ΠΏΠΎΠ΄ΠΎΠ±Π½Ρ‹Π΅ ΠΊΠΎΠΌΠ±ΠΈΠ½ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹Π΅ томографичСскиС систСмы ΠΎΡ‚Π»ΠΈΡ‡Π°ΡŽΡ‚ΡΡ высокой ΡΡ‚ΠΎΠΈΠΌΠΎΡΡ‚ΡŒΡŽ ΠΈ ΠΌΠ°Π»ΠΎ доступны для использования Π² ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅. ΠŸΡ€ΠΈΠΌΠ΅Π½ΡΠ΅ΠΌΡ‹Π΅ Π°Π»Π³ΠΎΡ€ΠΈΡ‚ΠΌΡ‹ для совмСщСния Π΄Π°Π½Π½Ρ‹Ρ…, ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½Ρ‹Ρ… Π½Π° ΠΎΡ‚Π΄Π΅Π»ΡŒΠ½Ρ‹Ρ… томографичСских установках, ΠΊΠ°ΠΊ ΠΏΡ€Π°Π²ΠΈΠ»ΠΎ, Ρ‚Π°ΠΊΠΆΠ΅ Ρ‚Ρ€Π΅Π±ΡƒΡŽΡ‚ использования дорогостоящСго оборудования ΠΈ ΡΠ»ΠΎΠΆΠ½ΠΎΠ³ΠΎ ΠΏΡ€ΠΎΠ³Ρ€Π°ΠΌΠΌΠ½ΠΎΠ³ΠΎ обСспСчСния [Walhl R.L. et al., 1993, Hill D.L.G. et al., 2001]. Π’ ΡΠ²ΡΠ·ΠΈ с ΡΡ‚ΠΈΠΌ вСсьма Π°ΠΊΡ‚ΡƒΠ°Π»ΡŒΠ½ΠΎΠΉ ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌΠΎΠΉ являСтся Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΈ ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠ°Ρ апробация эффСктивной ΠΈ ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ простой Ρ‚Π΅Ρ…Π½ΠΎΠ»ΠΎΠ³ΠΈΠΈ совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ, ΠΏΡ€ΠΈΠ³ΠΎΠ΄Π½ΠΎΠΉ для ΡˆΠΈΡ€ΠΎΠΊΠΎΠ³ΠΎ примСнСния Π² ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅.

ЦСль ΠΈ Π·Π°Π΄Π°Ρ‡ΠΈ исслСдования

ЦСлью исслСдования явилась Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΈ ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠ°Ρ апробация эффСктивной Ρ‚Π΅Ρ…Π½ΠΎΠ»ΠΎΠ³ΠΈΠΈ совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ для выявлСния, Π΄ΠΈΡ„Ρ„Π΅Ρ€Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½ΠΎΠΉ диагностики, Π° Ρ‚Π°ΠΊΠΆΠ΅ ΠΎΡ†Π΅Π½ΠΊΠΈ эффСктивности лСчСния ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅ΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½ΠΎΠΉ Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ ΠΈ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Π½Π΅ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅Π²Ρ‹Ρ… Π·Π°Π±ΠΎΠ»Π΅Π²Π°Π½ΠΈΠΉ Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π°. Для Ρ€Π΅Π°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ этой Ρ†Π΅Π»ΠΈ слСдовало Ρ€Π΅ΡˆΠΈΡ‚ΡŒ ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠ΅ Π·Π°Π΄Π°Ρ‡ΠΈ: Π Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Ρ‚ΡŒ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΡƒ совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ с ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ Π΄Π°Π½Π½Ρ‹Ρ… MPT, МБКВ, ПЭВ с 18Π -Π€Π”Π“.

ΠžΠΏΡ€Π΅Π΄Π΅Π»ΠΈΡ‚ΡŒ Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΌΠΎΠ΄ΠΈΡ„ΠΈΠΊΠ°Ρ†ΠΈΠΉ совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Π² ΡƒΡΠ»ΠΎΠ²ΠΈΡΡ… экспСримСнта ΠΈ ΠΏΡ€ΠΈ обслСдовании Π±ΠΎΠ»ΡŒΠ½Ρ‹Ρ… с Π·Π°Π±ΠΎΠ»Π΅Π²Π°Π½ΠΈΡΠΌΠΈ Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΎΡ€Π³Π°Π½ΠΎΠ². ΠžΠΏΡ€Π΅Π΄Π΅Π»ΠΈΡ‚ΡŒ Π΄ΠΈΠ°Π³Π½ΠΎΡΡ‚ΠΈΡ‡Π΅ΡΠΊΡƒΡŽ ΡΡ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π½ΠΎΠ³ΠΎ ΠΌΠ΅Ρ‚ΠΎΠ΄Π° совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Π² ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅ Π½Π° ΠΎΡΠ½ΠΎΠ²Π΅ Π΄Π°Π½Π½Ρ‹Ρ… ПЭВ с 18Π -Π€Π”Π“, МРВ ΠΈ ΠœΠ‘КВ.

Новизна исслСдования. Π Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π° ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° совмСщСния Π»ΡƒΡ‡Π΅Π²Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ (ПЭВ, МБКВ, МРВ), Ρ…Π°Ρ€Π°ΠΊΡ‚Π΅Ρ€ΠΈΠ·ΡƒΡŽΡ‰Π°ΡΡΡ ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ высокими показатСлями точности рСгистрации ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… Π΄Π°Π½Π½Ρ‹Ρ…. Π’ΠΏΠ΅Ρ€Π²Ρ‹Π΅ Π½Π° ΠΎΠ±ΡˆΠΈΡ€Π½ΠΎΠΌ клиничСском ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Π΅ установлСна высокая ΡΡ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π½ΠΎΠΉ Ρ‚Π΅Ρ…Π½ΠΎΠ»ΠΎΠ³ΠΈΠΈ совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Π² ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅ для выявлСния, Π΄ΠΈΡ„Ρ„Π΅Ρ€Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½ΠΎΠΉ диагностики, ΠΎΡ†Π΅Π½ΠΊΠΈ эффСктивности Π»ΡƒΡ‡Π΅Π²ΠΎΠ³ΠΎ (Π² Ρ‚ΠΎΠΌ числС стСрСотаксичСского) ΠΈ Ρ…ирургичСского лСчСния ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅ΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½ΠΎΠΉ Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Π½Π΅ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅Π²Ρ‹Ρ… Π·Π°Π±ΠΎΠ»Π΅Π²Π°Π½ΠΈΠΉ Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π°.

ΠŸΡ€Π°ΠΊΡ‚ΠΈΡ‡Π΅ΡΠΊΠ°Ρ Π·Π½Π°Ρ‡ΠΈΠΌΠΎΡΡ‚ΡŒ Ρ€Π°Π±ΠΎΡ‚Ρ‹. ΠŸΡ€Π°ΠΊΡ‚ΠΈΡ‡Π΅ΡΠΊΠ°Ρ Π·Π½Π°Ρ‡ΠΈΠΌΠΎΡΡ‚ΡŒ Ρ€Π°Π±ΠΎΡ‚Ρ‹ Π·Π°ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ΡΡ Π² ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ простотС ΠΏΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½Π½ΠΎΠ³ΠΎ ΠΌΠ΅Ρ‚ΠΎΠ΄Π° совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ, Π½Π΅ Ρ‚Ρ€Π΅Π±ΡƒΡŽΡ‰Π΅Π³ΠΎ использования слоТного ΠΏΡ€ΠΎΠ³Ρ€Π°ΠΌΠΌΠ½ΠΎΠ³ΠΎ ΠΈ Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠ³ΠΎ тСхничСского обСспСчСния. Π‘ΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠ² Π²ΠΈΠ·ΡƒΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ (МРВ, МБКВ, ПЭВ) Π΄Π°Π΅Ρ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ ΠΎΠ΄Π½ΠΎΠ²Ρ€Π΅ΠΌΠ΅Π½Π½ΠΎ ΠΏΠΎΠ»ΡƒΡ‡ΠΈΡ‚ΡŒ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡŽ ΠΎ ΡΡ‚Ρ€ΡƒΠΊΡ‚ΡƒΡ€Π½ΠΎ-Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½ΠΎΠΌ состоянии исслСдуСмой анатомичСской области, Ρ‡Ρ‚ΠΎ, Π² ΡΠ²ΠΎΡŽ ΠΎΡ‡Π΅Ρ€Π΅Π΄ΡŒ, позволяСт ΠΏΠΎΠ²Ρ‹ΡΠΈΡ‚ΡŒ ΡΡ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ Π»ΡƒΡ‡Π΅Π²ΠΎΠΉ диагностики. Π Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Ρ‹ Ρ€Π΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°Ρ†ΠΈΠΈ ΠΏΠΎ ΠΎΠΏΡ‚ΠΈΠΌΠ°Π»ΡŒΠ½ΠΎΠΌΡƒ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡŽ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Π² Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… клиничСских ситуациях, ΠΏΠΎΠ²Ρ‹ΡˆΠ°ΡŽΡ‰ΠΈΠ΅ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ комплСксного Π»ΡƒΡ‡Π΅Π²ΠΎΠ³ΠΎ исслСдования. Π’Π½Π΅Π΄Ρ€Π΅Π½ΠΈΠ΅ Π² ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΡƒ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½Π½ΠΎΠΉ Ρ€Π°Π±ΠΎΡ‚Ρ‹ Π±ΡƒΠ΄Π΅Ρ‚ ΡΠΏΠΎΡΠΎΠ±ΡΡ‚Π²ΠΎΠ²Π°Ρ‚ΡŒ ΠΏΠΎΠ²Ρ‹ΡˆΠ΅Π½ΠΈΡŽ эффСктивности диагностики ΠΈ Π»ΡƒΡ‡Π΅Π²ΠΎΠΉ Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ Π±ΠΎΠ»ΡŒΠ½Ρ‹Ρ… с ΠΎΠΏΡƒΡ…олями Ρ€Π°Π·Π»ΠΈΡ‡Π½ΠΎΠΉ Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ ΠΈ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΌΠΈ Π΄Ρ€ΡƒΠ³ΠΈΠΌΠΈ заболСваниями.

ΠžΡΠ½ΠΎΠ²Π½Ρ‹Π΅ полоТСния, выносимыС Π½Π° Π·Π°Ρ‰ΠΈΡ‚Ρƒ. ΠŸΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ совмСщСния ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Π² ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅ позволяСт ΡƒΠ²Π΅Π»ΠΈΡ‡ΠΈΡ‚ΡŒ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ Π»ΡƒΡ‡Π΅Π²ΠΎΠ³ΠΎ исслСдования Π² Π΄ΠΈΠ°Π³Π½ΠΎΡΡ‚ΠΈΠΊΠ΅ ΠΎΠΏΡƒΡ…ΠΎΠ»Π΅ΠΉ ΠΈ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Π΄Ρ€ΡƒΠ³ΠΈΡ… Π·Π°Π±ΠΎΠ»Π΅Π²Π°Π½ΠΈΠΉ, Π° Ρ‚Π°ΠΊΠΆΠ΅ ΠΎΠ±ΡŠΠ΅ΠΊΡ‚ΠΈΠ²Π½ΠΎ ΠΎΡ†Π΅Π½ΠΈΡ‚ΡŒ ΡΡ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΠΌΠΎΠ³ΠΎ лСчСния.

Ошибка рСгистрации мишСни зависит ΠΎΡ‚ Ρ‡ΠΈΡΠ»Π° ΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ² ΠΈ ΡΠ²Π»ΡΠ΅Ρ‚ся ΠΎΠ±ΡŠΠ΅ΠΊΡ‚ΠΈΠ²Π½Ρ‹ΠΌ ΠΊΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠ΅ΠΌ опрСдСлСния точности совмСщСния ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ. Для совмСщСния ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ ΠΎΡ‡Π°Π³ΠΎΠ² пораТСния, располоТСнных Π² Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… анатомичСских областях, Π² Π±ΠΎΠ»ΡŒΡˆΠΈΠ½ΡΡ‚Π²Π΅ случаСв цСлСсообразно ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒ Π½Π°Ρ€ΡƒΠΆΠ½Ρ‹Π΅ ΠΌΠ°Ρ€ΠΊΠ΅Ρ€Ρ‹, установлСнныС Π½Π° ΠΊΠΎΠΆΠ΅ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π° ΠΈΠ»ΠΈ стСрСотаксичСском Π°Π΄Π°ΠΏΡ‚Π΅Ρ€Π΅.

Апробация Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² Ρ€Π°Π±ΠΎΡ‚Ρ‹. ΠžΡΠ½ΠΎΠ²Π½Ρ‹Π΅ полоТСния Ρ€Π°Π±ΠΎΡ‚Ρ‹ Π΄ΠΎΠ»ΠΎΠΆΠ΅Π½Ρ‹ ΠΈ ΠΎΠ±ΡΡƒΠΆΠ΄Π΅Π½Ρ‹ Π½Π° ΠΠ΅Π²ΡΠΊΠΎΠΌ радиологичСском Ρ„ΠΎΡ€ΡƒΠΌΠ΅ (Π‘Π°Π½ΠΊΡ‚-ΠŸΠ΅Ρ‚Π΅Ρ€Π±ΡƒΡ€Π³, Π’ΠœΠ, 2003) — Π½Π° Π½Π°ΡƒΡ‡Π½ΠΎΠΉ ΠΊΠΎΠ½Ρ„Π΅Ρ€Π΅Π½Ρ†ΠΈΠΈ, посвящСнной 85-Π»Π΅Ρ‚ΠΈΡŽ со Π΄Π½Ρ основания ЦНИРРИ ΠœΠ— Π Π€ (Π‘Π°Π½ΠΊΡ‚-ΠŸΠ΅Ρ‚Π΅Ρ€Π±ΡƒΡ€Π³, 2003) — Π½Π° Π’сСроссийской Π½Π°ΡƒΡ‡Π½ΠΎ-практичСской ΠΊΠΎΠ½Ρ„Π΅Ρ€Π΅Π½Ρ†ΠΈΠΈ «ΠΠΊΡ‚ΡƒΠ°Π»ΡŒΠ½Ρ‹Π΅ ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌΡ‹ соврСмСнной Π½Π΅Π²Ρ€ΠΎΠ»ΠΎΠ³ΠΈΠΈ, психиатрии ΠΈ Π½Π΅ΠΉΡ€ΠΎΡ…ΠΈΡ€ΡƒΡ€Π³ΠΈΠΈ» (Π‘Π°Π½ΠΊΡ‚-ΠŸΠ΅Ρ‚Π΅Ρ€Π±ΡƒΡ€Π³, Π’ΠœΠ, 2003) — Π½Π° ΡΠ΅ΠΌΠΈΠ½Π°Ρ€Π΅ ΠΏΠΎ ΠΌΠ΅Π΄ΠΈΡ†ΠΈΠ½ΡΠΊΠΎΠΉ Π²ΠΈΠ·ΡƒΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ (Π—Π°Π»ΡŒΡ†Π±ΡƒΡ€Π³, Австрия, 2003). По Ρ‚Π΅ΠΌΠ΅ диссСртации ΠΎΠΏΡƒΠ±Π»ΠΈΠΊΠΎΠ²Π°Π½ΠΎ 3 ΡΡ‚Π°Ρ‚ΡŒΠΈ Π² Π²Π΅Π΄ΡƒΡ‰ΠΈΡ… клиничСских ΠΆΡƒΡ€Π½Π°Π»Π°Ρ… ΠΈ 3 Ρ€Π°Π±ΠΎΡ‚Ρ‹ Π² ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Π°Ρ… Π½Π°ΡƒΡ‡Π½Ρ‹Ρ… ΠΊΠΎΠ½Ρ„Π΅Ρ€Π΅Π½Ρ†ΠΈΠΉ. Π Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π½Ρ‹Π΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡŽΡ‚ΡΡ Π² ΠΊΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΎΠΉ ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠ΅ ЦНИРРИ ΠœΠ— Π Π€.

ОбъСм ΠΈ ΡΡ‚Ρ€ΡƒΠΊΡ‚ΡƒΡ€Π° диссСртации. ДиссСртация состоит ΠΈΠ· Π²Π²Π΅Π΄Π΅Π½ΠΈΡ, ΠΎΠ±Π·ΠΎΡ€Π° Π»ΠΈΡ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Ρ‹, 4 Π³Π»Π°Π², Π·Π°ΠΊΠ»ΡŽΡ‡Π΅Π½ΠΈΡ, Π²Ρ‹Π²ΠΎΠ΄ΠΎΠ² ΠΈ ΡΠΏΠΈΡΠΊΠ° Π»ΠΈΡ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Ρ‹. Π Π°Π±ΠΎΡ‚Π° содСрТит 31 рисунок, 54 Ρ‚Π°Π±Π»ΠΈΡ†Ρ‹.

Бписок Π»ΠΈΡ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Ρ‹

Π²ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ 150 Π·Π°Ρ€ΡƒΠ±Π΅ΠΆΠ½Ρ‹Ρ… источников. ВСкст диссСртации ΠΈΠ·Π»ΠΎΠΆΠ΅Π½ Π½Π° 134 страницах машинописи.

Π²Ρ‹Π²ΠΎΠ΄Ρ‹.

1. Π‘ΠΎΠ²ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ мСдицинских ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ, ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ°ΡŽΡ‰ΠΈΡ… Π½Π°Ρ€ΡƒΡˆΠ΅Π½ΠΈΡ структуры исслСдуСмых ΠΎΡ€Π³Π°Π½ΠΎΠ² (МБКВ, МРВ) ΠΈ Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹Π΅ измСнСния Π² Π·ΠΎΠ½Π΅ пораТСния (ПЭВ) Ρƒ ΠΎΠ½ΠΊΠΎΠ»ΠΎΠ³ΠΈΡ‡Π΅ΡΠΊΠΈΡ… Π±ΠΎΠ»ΡŒΠ½Ρ‹Ρ…, позволяСт ΠΏΠΎΠ»ΡƒΡ‡ΠΈΡ‚ΡŒ Ρ†Π΅Π½Π½ΡƒΡŽ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡŽ ΠΎ Ρ…Π°Ρ€Π°ΠΊΡ‚Π΅Ρ€Π΅ ΠΈ Π»ΠΎΠΊΠ°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ патологичСских ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Π½ΠΈΠΉ, ΠΈΠΌΠ΅ΡŽΡ‰ΡƒΡŽ большоС Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ для ΠΏΠΎΡΠ»Π΅Π΄ΡƒΡŽΡ‰Π΅Π³ΠΎ лСчСния.

2. ΠŸΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ ΠΌΠ΅Ρ‚ΠΎΠ΄Π° совмСщСния Π»ΡƒΡ‡Π΅Π²Ρ‹Ρ… ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Ρƒ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² с Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΌΠΈ нСйропсихичСскими расстройствами Π΄Π°Π΅Ρ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ ΠΈΠ΄Π΅Π½Ρ‚ΠΈΡ„ΠΈΡ†ΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ ΠΏΠΎΡ€Π°ΠΆΠ΅Π½Π½Ρ‹Π΅ структуры Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° ΠΈ Π² Ρ€Π°Π½Π½ΠΈΠ΅ сроки ΠΎΠ±ΡŠΠ΅ΠΊΡ‚ΠΈΠ²Π½ΠΎ ΠΎΡ†Π΅Π½ΠΈΡ‚ΡŒ ΡΡ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ стСрСотаксичСского (хирургичСского ΠΈ Π»ΡƒΡ‡Π΅Π²ΠΎΠ³ΠΎ), Π° Ρ‚Π°ΠΊΠΆΠ΅ лСкарствСнного лСчСния.

3. НаиболСС ΠΎΠ±ΡŠΠ΅ΠΊΡ‚ΠΈΠ²Π½Ρ‹ΠΌ ΠΊΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠ΅ΠΌ ΠΎΡ†Π΅Π½ΠΊΠΈ точности совмСщСния являСтся ошибка рСгистрации мишСни, Ρ‚Π°ΠΊ ΠΊΠ°ΠΊ этот ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»ΡŒ нСпосрСдствСнно ΠΎΡ‚Ρ€Π°ΠΆΠ°Π΅Ρ‚ ΠΎΡ‚ΠΊΠ»ΠΎΠ½Π΅Π½ΠΈΠ΅ ΠΈΠ·ΠΎΡ†Π΅Π½Ρ‚Ρ€ΠΎΠ² области интСрСса (ΠΎΡ‡Π°Π³Π° пораТСния) Π½Π° ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… изобраТСниях.

4. Ошибка рСгистрации мишСни находится Π² ΠΎΠ±Ρ€Π°Ρ‚Π½ΠΎΠΉ коррСляционной зависимости ΠΎΡ‚ Ρ‡ΠΈΡΠ»Π° Π½Π°Ρ€ΡƒΠΆΠ½Ρ‹Ρ… ΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ² ΠΈ Π·Π°Π²ΠΈΡΠΈΡ‚ ΠΎΡ‚ ΠΈΡ… ΠΊΠΎΠ½Ρ„ΠΈΠ³ΡƒΡ€Π°Ρ†ΠΈΠΈ.

5. ΠŸΡ€ΠΈ ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠΈ исслСдований Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° Π±Π΅Π· стСрСотаксичСского Π°Π΄Π°ΠΏΡ‚Π΅Ρ€Π° допустимо совмСщСниС ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ с ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ Π²Π½ΡƒΡ‚Ρ€Π΅Π½Π½ΠΈΡ… ΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ². ΠŸΡ€ΠΈ стСрСотаксичСских исслСдованиях Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π°, Π° Ρ‚Π°ΠΊΠΆΠ΅ патологичСских измСнСниях Π² Π΄Ρ€ΡƒΠ³ΠΈΡ… анатомичСских областях Ρ€Π΅Π³ΠΈΡΡ‚Ρ€Π°Ρ†ΠΈΡŽ ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… Π΄Π°Π½Π½Ρ‹Ρ… цСлСсообразно Π²Ρ‹ΠΏΠΎΠ»Π½ΡΡ‚ΡŒ ΠΏΠΎ Π½Π°Ρ€ΡƒΠΆΠ½Ρ‹ΠΌ ΠΌΠ°Ρ€ΠΊΠ΅Ρ€Π°ΠΌ.

ΠŸΡ€Π°ΠΊΡ‚ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ Ρ€Π΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°Ρ†ΠΈΠΈ.

1. ΠŸΡ€ΠΈ ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠΈ совмСщСния ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠΌ ТСсткой трансформации ΠΌΡƒΠ»ΡŒΡ‚ΠΈΠΌΠΎΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… Π΄Π°Π½Π½Ρ‹Ρ… Ρ€Π°Π·ΠΌΠ΅Ρ€ ΠΌΠ°Ρ‚Ρ€ΠΈΡ†Ρ‹ ΠΈ ΠΏΠΈΠΊΡΠ΅Π»Π° ПЭВ ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ слСдуСт ΠΏΡ€ΠΈΠ²ΠΎΠ΄ΠΈΡ‚ΡŒ ΠΊ Π°Π½Π°Π»ΠΎΠ³ΠΈΡ‡Π½Ρ‹ΠΌ показатСлям ΠšΠ’ ΠΈΠ»ΠΈ МРВ для прСдотвращСния ΠΏΠΎΡ‚Π΅Ρ€ΠΈ качСства послСдних.

2. Для опрСдСлСния ошибки рСгистрации мишСни ΠΌΠ°Ρ€ΠΊΠ΅Ρ€-мишСнь Π΄ΠΎΠ»ΠΆΠ΅Π½ находится нСпосрСдствСнно Π½Π°Π΄ Π·ΠΎΠ½ΠΎΠΉ интСрСса для получСния ΠΎΠ±ΡŠΠ΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΠΉ ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΠΈ ΠΎ Π²Π΅Π»ΠΈΡ‡ΠΈΠ½Π΅ этого показатСля.

3. ΠŸΡ€ΠΈ совмСщСнии ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° с ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ΠΌ стСрСотаксичСского Π°Π΄Π°ΠΏΡ‚Π΅Ρ€Π° число Π½Π°Ρ€ΡƒΠΆΠ½Ρ‹Ρ… ΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ² Π΄ΠΎΠ»ΠΆΠ½ΠΎ Π±Ρ‹Ρ‚ΡŒ максимально Π²ΠΎΠ·ΠΌΠΎΠΆΠ½Ρ‹ΠΌ, Ρ‚Π°ΠΊ ΠΊΠ°ΠΊ это ΠΏΠΎΠ·Π²ΠΎΠ»ΠΈΡ‚ сущСствСнно ΡƒΠΌΠ΅Π½ΡŒΡˆΠΈΡ‚ΡŒ ΠΎΡˆΠΈΠ±ΠΊΡƒ рСгистрации мишСни.

4. Π£ΠΊΠ»Π°Π΄ΠΊΠ° ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² Π²ΠΎ Π²Ρ€Π΅ΠΌΡ сканирования ΠΏΡ€ΠΈ ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠΈ КВ, МРВ Π΄ΠΎΠ»ΠΆΠ½Π° Π±Ρ‹Ρ‚ΡŒ максимально ΠΏΡ€ΠΈΠ±Π»ΠΈΠΆΠ΅Π½Π° ΠΊ ΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΡŽ больного Π½Π° Ρ‚омографичСском столС ПЭВ. Π­Ρ‚ΠΎ Π΄Π°Π΅Ρ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ Π·Π½Π°Ρ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ ΡƒΠΌΠ΅Π½ΡŒΡˆΠΈΡ‚ΡŒ ошибки рСгистрации ΠΌΠ°Ρ€ΠΊΠ΅Ρ€ΠΎΠ² ΠΈ ΠΌΠΈΡˆΠ΅Π½ΠΈ.

ΠŸΠΎΠΊΠ°Π·Π°Ρ‚ΡŒ вСсь тСкст

Бписок Π»ΠΈΡ‚Π΅Ρ€Π°Ρ‚ΡƒΡ€Ρ‹

  1. Antoch G- Freudenberg LS- Egelhof T, et al. Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans. // J Nucl. Med. 2002.- V.43(10).- P.1339−42.
  2. Antoch G- Freudenberg LS- Stattaus J- et al. Whole-body positron emission tomography-CT: optimized CT using oral and IV contrast materials. //Am. J. Roentgenol. 2002.-V.179(6).-P. 1555−60
  3. Antoch G- Stattaus J- Nemat AT et al. Non-small cell lung cancer: dual-modality PET/CT in preoperative staging. //Radiology -2003- 229(2): 526−33.
  4. Antoch G- Vogt FM- Freudenberg LS et al. Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology. //JAMA -2003.-V. 290(24).- P, 3199−206.
  5. Arun KS, Huang TS, Blostein SD. Least-squares fitting of two 3-D point sets. //IEEE Trans Pattern Anal Mach Intell 1987.-V.9.- P. 698 700.
  6. Bai C- Kinahan PE- Brasse D, et al. An analytic study of the effects of attenuation on tumor detection in whole-body PET oncology imaging.//J.Nucl.Med.-2003.-V.44(11).-P. 1855−61.
  7. Barillot C. Surface and volume rendering techniques to display 3-D data, an overview of basic priples shows advances in display techniques. //IEEE Engineering in Medicine and Biology -1993,-V. 12(1).-P. 111−119.8.
  8. Barnden L., Kwiatek R., Lau Y., et al. Validation of fully automaticbrain SPET to MR co-registration // Eur. J. Nucl. Med. Mol. Imaging. -2000.-V. 27.- P. 147−154.
  9. Barra V., Boire J.V. A general framework for the fusion of anatomical and functional medical images. (Part 1.) // Neuroimage 2001.- V. 13. -P. 410−424.
  10. Barra V., Boire J.V. A general framework for the fusion of anatomical and functional medical images. (Part 2.) // Neuroimage 2001. — V. 13.1. P. 495−515.
  11. Bar-Shalom R., Yefremov N., Guralnik L. et al. Clinical performance of PET/CT in evaluation of cancer: additional value for diagnostic imaging and patient management. // J. Nucl. Med. 2003. — V. 44(8). — P. 12 001 209.
  12. Bartenstein P., Griinwald F., Kuwert T. et al. Clinical applications of single photon emission tomography in neuromedicine. // Nuklearmedizin. 2000.-V. 39.-P. 180−95.
  13. Benyounes H., Smith F.W., Campbell N.T.S. et al. Superimposition of PET images using 18 F-fluorodeoxyglucose with magnetic resonance images in patients with pancreatic carcinoma. // Nucl. Med. Commun. -1995.-V. 16.-P. 575−580.
  14. Beyer Π’., Townsend D.W., Brun T. A combined PET/CT scanner for clinical oncology. // J. Nucl. Med. 2000. — V.41(8). — P. 1369−1379.
  15. Beyer Π’., Watson C.C., Meltzer C.C. et al. The biograph: A Premium Dual-Modality PET/CT Tomograph for Clinical Oncology. // Electromedica. -2001.-V. 69. -P. 120−126.
  16. Beyer Π’., Townsend D.W., Blodgett T.M. Dual-modality PET/CT tomography for clinical oncology// J. Nucl. Med. -2002.- V.46(l).- P. 24−34.
  17. Beyer Π’., Yau Y.Y., Kaepplinger S. PET/CT tomography using a new PET detector material for ultra-fast imaging in clinical oncology. //Electromedica. 2002. -V.70. — P. 151−156.
  18. Beyer Π’., Antoch G., Blodgett T. et al. Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology.// Eur. J. Nucl. Med. Mol. Imaging 2003.- V.30(4).-P. 588−96.
  19. Bomanji J.B., Costa D. C, Ell P.J.Clinical role of positron emission tomography in oncology. // Lancet Oncol. 2001.- V. 2(3).- P. 157−64.
  20. Bookstein F.L., Green W.D. Edge information at landmarks in medical images. //Proceedings of the Second Conference on Visualization in Biomedical Computing, Chapel Hill, NC.- 1992.- P. 242−258.
  21. Boussion N., Cinotti L., Barra V. et al. Extraction of epileptogenic foci from PET and SPECT images by fuzzy modeling and data fusion. // Neuroimage—2003.—V.19(3).-P.645−654.
  22. Bristow R.E., del Carmen M.G., Pannu H.K. et al. Clinically occult recurrent ovarian cancer: patient selection for secondary cytoreductive surgery using combined PET/CT. // Gynecol. Oncol. -2003.- V.90(3).-P.519−528.
  23. Chajari M., Lacroix J., Peny A.M. et al. Gallium-67 scintigraphy in lymphoma: is there a benefit of image fusion with computed tomography? // Eur. J. Nucl. Med. Mol. Imaging — 2002. — V. 29(3).1. P. 380−387.
  24. Charron M., Beyer Π’., Bohnen N.N. et al. Image analysis in patients with cancer studied with a combined PET and CT scanner. //Clin. Nucl. Med.-2000.-V.25(l 1).P.-905−910.
  25. Chen C.T. Radiologic Image Registration: Old Skills and New Tools // Acad. Radiol. 2003.- V.10.-P.239−241.
  26. Cohade C., Osman M., Leal J., Wahl R.L. Direct comparison of (18)F-FDG PET and PET/CT in patients with colorectal carcinoma.// J Nucl Med.-2003 .-V.44(11).-P. 1797−803
  27. Cohade C., Osman M., Nakamoto Y., et al. Initial experience with oral contrast in PET/CT: phantom and clinical studies. //J Nucl Med -12 003 .-44(3).-412−416
  28. Cohade C., Wahl R.L. Applications of positron emission tomography/computed tomography image fusion in clinical positron emission tomography-clinical use, interpretation methods, diagnostic improvements.//Semin.Nucl.Med.-2003. — V.33(3).- P. 228−237.
  29. Duncan J. S: Imaging and epilepsy. //Brain 1997.- V. 120.- P. 339−337.
  30. Delbeke D., Martin W.H. Positron emission tomography imaging in oncology.//Radio.l Clin. North. Am. -2001.- V. 39(5).- P. 883−917.
  31. Dufner F., Schifbauer H., Breit S. et al. Relevance of Image Fusion for Target Point Determination in Functional Neurosurgery. // Acta Neurochir (Wien). 2002. — Vol. 144.-P.445 -451.
  32. Egidi M., Rampini P., Locatelli M. et al. Visualization of the subthalamic nucleus: a multiple sequential image fusion (MuSIF) technique for direct stereotaxic localisation and postoperative control.// Neurol. Sci.-2002.-V.23 .-Suppl.2.-P.71 -2
  33. Eggert D. W., Lorusso A., Fisher R. B, Estimating 3-D rigid body transformations: a comparison for four major algorithms // Mach. Vision Appl. 1997.-V.9.- P.272−290.
  34. Emri M., Esik O., Repa I., Marian Π’., Tron L. Image fusion of different tomographic methods (PET/CT/MRI) effectively contribute to therapy planning. // Orv. Hetil. 1997.- V.138(46).- P. 2919−24
  35. Eubank W.B., Mankoff D.A., Schmiedl U.P., Winter T.C.Fisher Imaging of oncologic patients: benefit of combined CT and FDG PET in the diagnosis of malignancy.//AJR 1998.- V.171.- P. l 103 -1110.
  36. Faist M., Xie J., Kurz D. Effect of bilateral subthalamic nucleus stimulation on gait in Parkinson’s disease. // Brain 2001.- V.124 (Pt. 8) P. 1590−600.
  37. Forster G.J., Laumann C., Nickel O., et al. SPET/CT image coregistration in the abdomen with a simple and cost-effective tool. // Eur. J. Nucl. Med. Mol. Imaging.-2003.-V.30(l).-P.32−39.
  38. Fitzpatrick J.M., West J.B., Maurer C.R.J. Predicting error in rigid-body point-based registration. //IEEE Trans. Med. Imaging 1998.-V.17.-P.694−702.
  39. Galloway R.L., Maciunas R.J., Edwards C.A. Interactive image guided neurosurgery. /Π›Π•Π•Π• Trans Biomedical Engineering 1992.- V.39(12).-P.l 126−1231.
  40. Garlick P.B., Marsden P.K., Cave A.C., et al. PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat hearts. // NMR.Biomed.-1997.-V.10(3).-P.138−142.
  41. Gerig G., Martin J., Kikinis R., et al. Unsupervised tissue type segmentation of 3-D dual MR head data.// Image and Vision Computing. 1992. — V. 10(6). — P. 349−360.
  42. Gingold E.L., Hasegawa B.H. Systematic bias in basis material decomposition applied to quantitative dual-energy x-ray imaging. // Med.Phys.-1992.-V. 19(1).-P.25−33.
  43. Goerres G.W., Burger C., Schwitter M.R. et al.- PET/CT of the abdomen: optimizing the patient breathing pattern. // Eur. Radiol. -2003.- V.13(4).- P. 734−739.
  44. Goshtasby A. Registration of images with geometric distortions //IEEE Trans. Geosci. Remote Sensing. 1988.- V. 26.- P.60−64.
  45. Goodall C. Procrustes methods in the statistical analysis of shape // J. R. Statist. Soc. Π’ .1991.- V.53.- P.285−339.
  46. Graham J.D., Warrington A.P., Gill S.S., Brada M. A noninvasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging. // Radiother. Oncology. 1991. — V.2. — P. 60−2.
  47. Griffin L. The intrinsic geometry of the cerebral cortex. Journal of Theoretical Biology.- 1994.-V. 166(3).- P. 261−273.
  48. Grova C., Jannin P., Biraben A. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy. // Phys.Med.Biol.-2003.-V.48(24).-P.4023−4043.
  49. Grzeszczuk R., Tan K.K., Levin D.N. et. al. Retrospective fusion of radiographic and MR data for localization of subdural electrodes. // J. Comput. Assist.Tomogr.-1992.-V. 16(5).-P.764−73.
  50. Guralnik L., Werbin N., Iosilevsky G., Israel O. The new technology of combined transmission and emission tomography in evaluation of endocrine neoplasms. //J. Nucl. Med. 2001.- V.42.- P.998 -1004.
  51. Hamilton R.J., Blend M.J., Pelizzari C.A., et al. Using vascular structure for CT-SPECT registration in the pelvis. // J. Nucl. Med. -1999.- V.40(2).- P. 347−51.
  52. Hasegawa B.H., Stebler Π’., Rutt B.K. A prototype high-purity germanium detector system with fast photon-counting circuitry for medical imaging. //Med. Phys. 1991. -V. 18(5). — P. 900−909.
  53. Hasegawa B.H., Wong K.H., Iwata K., et al. Dual-modality imaging of cancer with SPECT/CT.// Technol. Cancer. Res. Treat. -2002.- V. l (6). -P.449−58.
  54. Hasegawa B.H., Iwata K., Wong K.H., et al. Dual-modality imaging of function and physiology. //Acad. Radiol.- 2002.- V.9.- P.1305−1321.
  55. Hawkes D. J. The accuracy of 3D image registration using point landmarks. // Tech. Rep. RS94/1, UMDS, London, 1995.
  56. Hawkes D.J. Algorithms for radiological image registration and their clinical application. // J. Anat. 1998.- V.193.- P. 347−361.
  57. Hill D.L.G. Combination of 3D medical images from multiple modalities. //University of London, 1993.
  58. Hill D. L. G, Hawkes D. J., Gleeson M. J., et al. Accurate frameless registration of MR and CT images of the head: Applications in surgery and radiotherapy planning. // Radiology 1994.-Y. 191.- P.447−454.
  59. Hill D. L. G., Maurer Jr .C. R et al. Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm.// J. Comput. Assist. Tomogr 1998.- V22.- P.317−323.
  60. Hill D.L.G., Batchelor P.G., Holden M., Hawkes D.J. Medical image registration. //Phys. Med. Biol. 2001.- V.46.-R1-R45.
  61. Hum M.A., Mardia K.V., Hainsworth T.J., et al. Bayesian fused classification of medical images. // IEEE Trans. Medical Imaging. -1996.-V. 15.-P. 259−302.
  62. Jiang H., Robb R.A., Holton K.S. A new approach to 3-D registration of multimodality images by surface matching. //Proceedings of the Second Conference on Visualization in Biomedical Computing, Chapel Hill, NC.-1992.-P. 196−213.
  63. Julow J., Major Π’., Valalik I. The Application of Image Fusion in Stereotactic Brachytherapy of Brain Tumours// Acta Neurochir (Wien). -2000.- V.142: P.1253−1258.
  64. Imth G. Graphics applied to medical image registration/. //IEEE Comput. Graph. Appl., March 1991.- V. 11.- P.20−29.
  65. Kamel E.M., Burger C., Buck A. Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner. // Eur. Radiol,-2003.-V.13(4).-P.724−728.
  66. Kaiboriboon K., Lowe V.J., Chantarujikapong S.I. Hogan RE The usefulness of subtraction ictal SPECT coregistered to MRI in single-and dual-headed SPECT cameras in partial epilepsy. // Epilepsia -2002.- V.43(4).-P. 408−414.
  67. Kashiwagi Π’., Yutani К., Fukuchi M. et al. Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT. // Ann. Nucl. Med. 2002.- V.16(4).- P.255−61.
  68. Kawaharada Y., Itou A. Registration of chest PET and CT images-fusion technique using the PET/Tr image by the respiration compensation. // Kaku Igaku Japanese Journal of Nuclear Medicine] - 2003.-V.40(l).-P.l-9.
  69. Kinahan P.E., Hasegawa B.H., Beyer T. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. // Semin. Nucl. Med. 2003. — V. 33(3). — P. 166−79.
  70. Kluetz P.G., Meltzer C.C., Villemagne M.G. et al. Combined PET/CT imaging in oncology: impact on patient managment. //Clin. Positron. Imaging. 2000.- V. 3. — P. 223 — 230.
  71. Lang T.F., Hasegawa B.H., Liew S.C. et al. Description of a prototype emission-transmission computed tomography imaging system.//J.Nucl.Med.-l 992.-V.33(l 0).-P. 1881−7.
  72. Liew S.C., Hasegawa B.H. Noise, resolution, and sensitivity considerations in the design of a single-slice emission-transmission computed tomographic system. // Med. Phys. — 1991. -V.18(5). — P. 1002−15.
  73. Levin D.N., Pelizzari C.A., Chen G.T.Y. et al. Retrospective geometric correlation of MR, CT, and PET images. // Radiology 1988.- V.169.-P. 817−823.
  74. Loats H. CT and SPECT image registration and fusion for spatial localization of metastatic processes using radiolabeled monoclonals. //
  75. J. Nucl. Med.-1993.- V.34(3 Suppl).- P.562−566.
  76. Maintz J.B.A., Viergever M.A. A survey of medical image registration. //Med. Image. Anal. 1998.-V. 2.-P.1−36.
  77. Maurer C.R., Mc Croy J.J., Fitzpatrick J.M. Estimation of accuracy in localizing externally attached markers in multimodal volume head images. //In: Loew MH, ed. Proc SPIE V.1898. Medical Imaging 1993: Image Processing 1993.- V.12.-P.43−54.
  78. Maurer C.R., Fitzpatrick J.M., A review of medical image registration. //In Interactive Image-Guided Neurosurgery (R. J. Maciunas, ed.), P. 17−44, Park Ridge, IL: American Association of Neurological Surgeons, 1993.
  79. Mandava V. R., Fitzpatrick J. M., Maurer Jr. C. R. et al. Registration of multimodal volume head images via attached markers. // Medical Imaging VI: Image Processing 1992. Vol. Proc. SPIE 1652, P. 271 282.
  80. Myers R .The application of PET-MR image registration in the brain. // Br.J.Radiol.-2002.-V.75.-Spec.-No.-S.31−35.
  81. Nakamoto Y., Osman M., Cohade C. et al. PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images. // J. Nucl. Med. 2002.- V.43(9).- P. 113 743.
  82. Nakamoto Y., Chin B.B., Kraitchman D.L. et al. Effects of nonionic intravenous contrast agents at PET/CT imaging: phantom and canine studies.//Radiology-2003.-V.227(3).-P.817−824.
  83. Nakamoto Y., Tatsumi M., Cohade C. et al. Accuracy of image fusion of normal upper abdominal organs visualized with PET/CT. //Eur. J. Nucl.Med.Mol.Imaging-2003.-V.30(4).-P.597−602.
  84. Nishioka Π’., Shiga Π’., Shirato H. et al. Image fusion between 18FDG-PET and MRI/CT for radiotherapy planning of oropharyngeal and nasopharyngeal carcinomas. //Int. J. Radiat. Oncol. Biol. Phys. --2002,-V.53(4).- P.1051−1057.
  85. Minotti A.J., Shah L., Keller K. Positron emission tomography/computed tomography fusion imaging in brown adipose tissue. // Clin. Nucl. Med.- 2004.-29(1).- P. 5−11.
  86. Oberg K. Neuroendocrine gastrintestinal tumors — a condensed overview of diagnosis and treatment.//Ann. Oncol. 1999.V.10.-P.53 -58.
  87. Olivier A., Germano I.M., Cukiert A., Peters T. Frameless stereotaxy for surgery of the epilepsies: preliminary experience. Technical note. // J.Neurosurg.-1994.-V.81 (4).-P.629−633.
  88. Osman M.M., Cohade C., Nakamoto Y., Wahl R.L. Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT. Eur. J. Nucl. Med. Mol. Imaging — 2003.-V.30(4).-P.603−6.
  89. Osman M.M., Cohade C., Nakamoto Y., et al.- Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients. // J. Nucl. Med. 2003.- V.44(2).- P.240−3.
  90. Pannu H.K., Bristow R.E., Cohade C. et al. PET-CT in recurrent ovarian cancer: initial observations. // Radiographics — 2004.1. V.24(l).- P.209−223.
  91. Patel P.V., Cohade C., Chin B.B. PET-CT localizes previously undetectable metastatic lesions in recurrent fallopian tube carcinoma. // Gynecol. Oncol. -2002.- V.87(3).- P.323−6.
  92. Patton J.A., Debelke D., Sandler M.P. Image fusion using an integrated, dual-head coincidence camera with x-ray tube-based attenuation maps.//J. Nucl. Med. 2000.- V.41.- P. 1364 -1368.
  93. Pelizzari C.A. Image processing in stereotactic planning: volume visualization and image registration. // Med. Dosim.-1998.- 23(3).- P. 137−145.
  94. Pelizzari C. A., Chen G. T. Y., Spelbring D. R. et al. Accurate three-dimensional registration of CT, PET, and/or MR images of the brain, // J. Comput. Assist. Tomogr. 1989.- V. 13.- P. 20−26.
  95. Pernus F., Stiehl H.S., Viergever M.A., eds. Special issue on biomedical image registration. // Image Vis. Comput. 2001.- V.19.-P.l-96.
  96. Peters A.R., Muller S.H., de Munck J.C., van Herk M. The accuracy of image registration for the brain and the nasopharynx using external anatomical landmarks. // Phys. Med. Biol. 2000.- V.45(8).- P.2403−2416.
  97. Pietrzyk U., Herholz K., Heiss W.D. Three-dimensional alignment of functional and morphological tomograms. // J. Comput. Assist. Tomogr. 1990 — V. 14(1). — P. 51 -59.
  98. Pietrzyk U., Herholz K, Schuster A. et al. Clinical applications of registration and fusion of multimodality brain images from PET,
  99. SPECT, CT, and MRI. // Eur. J. Radiol. -1996.- V.21(3).-P.174−182.
  100. Pfannenberg A.C., Eschmann S.M., Horger M. et al. Benefit of anatomical-functional image fusion in the diagnostic work-up of neuroendocrine neoplasms. //Eur. J. Nucl. Med. Mol. Imaging. -2003.-V.30(6).- P.835−43.
  101. Pfluger Π’., Vollmar C., Wismuller A. et al. Quantitative comparison of automatic and interactive methods for MRI-SPECT image registration of the brain based on 3-dimensional calculation of error. // J. Nucl. Med. -2000.- V.41(l 1).-P. 1823−9.
  102. Rampini P.M., Locatelli M., Alimehmeti R. et al. Multiple sequential image-fusion and direct MRI localisation of the subthalamic nucleus for deep brain stimulation. // J. Neurosurg. Sci.-2003.- V.47(l).-P.33−39.
  103. Robb R.A. A software system for interactive and quantitative analysis of biomedical images. In: Hohne KH, Fuchs H, Pizer SM: 3D Imaging in Medicine, NATO ASI Series 1990.- V. F 60.- P.333−361.
  104. Rueckert D., Sonoda L., Hayes C., Hill D.L.G., Leach M., Hawkes D.J. Non-rigid registration using freeform deformations: appli-cation to breast MR images. //IEEE Trans. Med. Imaging. 1999.- V.18.-P.712−721.
  105. Ryan M.J., Erickson R.K., Levin D.N. et al. Frameless stereotaxy with real-time tracking of patient head movement and retrospective patient-image registration. // J. Neurosurg. 1996.- V.85(2).- P.287−292.
  106. Sannazzari G.L., Ragona R., Ruo Redda M.G. et al. CT-MRI image fusion for delineation of volumes in three-dimensional conformalradiation therapy in the treatment of localized prostate cancer. // Br. J. Radiol.-2002.- V.75(895).- P.603−607.
  107. Schellingerhout D., Lev M.H., Bagga R.J. et al. Coregistration of head CT comparison studies: assessment of clinical utility. // Acad. Radiol. -2003, — V.10.- P.242—248.
  108. Schoder H., Erdi Y.E., Larson S.M., Yeung H.W. PET/CT: a new imaging technology in nuclear medicine.// Eur. J. Nucl. Med. Mo. l Imaging 2003.- V.30(10).- P. 1419−1437.
  109. V., Chauveinc L., Π•.1., Khoury C. Et al. CT and MR image fusion using two different methods after prostate brachytherapy: impact on post-implant dosimetric assessment Cancer Radiother. 2003-.-7(1).- P.9−16.
  110. Shao Y., Cherry S.R., Farahani K. et al. Simultaneous PET and MR imaging. // Phys. Med. Biol.- 1997. V. 42(10). — P. 1965−70.
  111. Shreve P.D. Adding structure to function (invited commentary). //J. Nucl. Med. -2000.-V. 41.-P. 1380−1382.
  112. Studholme Π‘., Hill D. L. G., Hawkes D. J., Automated 3D registration of MR and CT images of the head, // Med. Image Anal. 1996 — V.I.-P. 163−175.
  113. Studholme C., Hill D. L. G., Hawkes D. J. Automated 3D registration of MR and PET brain images by multi-resolution optimisation of voxel similarity measures. // Med. Phys.- 1997.- V. 24.- P.25−35.
  114. Stytz M.R., Frieder G., Frieder O. Three-dimensional medical imaging: algorithms and computer systems.//ACM Computer Surveys 1991.-V.23(4).-P.421−499.
  115. Sure U., Benes L. U. Image fusion for skull base neuronavigation-technical note //Neurol. Med.Chir. (Tokyo) 2002.- V.42(10).-P. 45 862.
  116. Suri J.S. Two dimensional fast MR brain segmentation using a region-based level set approach. International Journal of Engin-eering in Medicine and Biology.-2001.- P. 14−15.
  117. Suri J.S., Setarehdan S.K., Singh S. Advanced Algorithmic Approaches to Medical Image Segmentation: State-of-the-Art Applications in Cardiology, Neurology, Mammography and Pathology. Springer, London, 2001.
  118. Tan K.K., Grzeszczuk R., Levin D.N. A frameless stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note. //J.Neurosurg.-1993.-V.79(2).- P.296−303.
  119. Tang H.R., Da Silva A.J., Matthay K.K. et al. Neuroblastoma imaging using a combined CT scanner-scintillation camera and 131I-MIBG.// J. Nucl. Med. 2001. — V. 42(2). — P. 237−47.
  120. Tatsumi M., Cohade Π‘., Nakamoto Y., Wahl R.L. Fluorodeoxyglucose uptake in the aortic wall at PET/CT: possible finding for active atherosclerosis.//Radiolog.-2003.-V.229(3).-P.831−7.
  121. Thomas C.T., Meyer C.R., Koeppe R.A. et al. A positron-emitting internal marker for identification of normal tissue by positron emission tomography: phantom studies and validation in patients. // Mol. Imaging. Biol.-2003.-V.5(2).- P.79−85.
  122. Toet A., Franken E. M. Perceptual evaluation of different image fusion schemes. // 2003. Displays.- V. 24, — no.l.- P. 25−37.
  123. Townsend D.W., Cherry S.R. Combining anatomy and function: the path to true image fusion. //Eur. Radiol. 2001.- V. 11.- P. 1968−1974.
  124. Townsend D.W. A combined PET/CT scanner: the choices. // J Nucl. Med.-2001.- V.42(3).- P.533−534.
  125. Townsend D.W., Beyer T. A combined PET/CT scanner: the path to true image fusion. // Br. J. Radiol. 2002.- V.75 Spec No: S24−30.
  126. Townsend D.W., Beyer Π’., Blodgett T.M. PET/CT scanners: a hardware approach to image fusion.//Semin. Nucl. Med. — 2003.-V.33(3).-193−204.
  127. Thurfjell L., Pagani M. Andersson J.L.R. et al. Registration of neuroimaging data Implementation and clinical applications //J.Neuroim—2000.-V.10.-P.39−46.
  128. Turkington T.G., Hoffman J.M., Jaszczak R.J. Accuracy of surface fit registration for PET and MR brain images using full and incomplete brain surfaces. //J. Comput. Assist. Tomog. 1995.-V. 19(1).- P. 117
  129. Turkington T.G., Jaszczak R.J., Pelizzari C.A., Harris C.C., MacFall J.R., Hoffman J.M., Coleman R.E. Accuracy of registration of PET, SPECT and MR images of a brain phantom. //J. Nucl. Med. 1993.-V.34.- P. 1587−1594.
  130. Van den Elsen P.A., Pol E.J.D., Viergever M.A. Medical image matching: a review with classification. // IEEE Trans. Eng. Biol.-1993.-V. 12.-P.26−39.
  131. Van Heertum R.L., Drocea C., Ichise M. et al. Single photon emission CT and positron emission tomography in the evaluation of neurologic disease. // Radiol. Clin. North. Am. -2001.-V.39(5).- P. 1007−33.
  132. Visvikis D., Costa D.C., Croasdale I. et al. CT-based attenuation correction in the calculation of semi-quantitative indices of 18FJFDG uptake in PET. // Eur. J. Nucl. Med. Mol. Imaging. -2003.-V.30(3).-344−353.
  133. Wahl R.L., Quint L.E., Cieslak R.D., Aisen A.M., et al. «Anatometabolic» tumour imaging: fusion of FDG PET with CT or MR to localize foci of increased activity.//J. Nucl. Med. 1993.- V.34.-P.l 190−1197.
  134. Wahl R.L. Progress in nuclear medicine imaging of cancers. // Prim. Care. -1998.- V.25(2).-341−346.
  135. Wahl R.L. Anatomolecular imaging with 2-deoxy-2-18 °F.fluoro-D-glucose: bench to outpatient center. // Mol. Imaging. Biol. -2003.-V.5(2).-P.49−56.
  136. Wang M. Y., Fitzpatrick J. M., Maurer C. R. Jr., Maciunas R. J, Anautomatic technique for localizing externally attached markers in MR and CT volume images of the head. // Medical. Imaging.- 1994 Image Processing — V. Proc. SPIE 2167.- P. 214−224.
  137. Wang Z., Bovik A.C. A universal image quality index. // IEEE Signal Processing Letters. 2002.- V. 9.- β„–.3.- P. 81−84.
  138. West J.B., Fitzpatrick J.M., Toms S.A. et al. Fiducial point placement and the accuracy of point-based, rigid body registration. //Neurosurgery -2001 .-V.48(4).-P.810−6-discussion.-P.816−817.
  139. West J.B., Fitzpatrick J.M., Wang M.Y. et al. Comparison and evaluation of retrospective intermodality brain image registration techniques. // J. Comput. Assist. Tomogr.- 1998 .- V.21.- P. 554−566.
  140. Wong J.C.H., Studholme C., Hawkes D.J., Maisey M.N. Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study. //Eur J. Nucl. Med. -1997.- V.24.- P.642−650.
  141. Woods R.P., Mazziotta J.C., Cherry S.R., MRI-PET registration with automated algorithm, // J. Comput. Assist. Tomogr. 1993. — V.17.- P. 536−546.
  142. Wu X., Brown JK., Kalki K., Hasegawa B.H. Characterization and correction of pulse pile-up in simultaneous emission-transmissioncomputed tomography. // Med Phys. 1996. -V. 23(4). — P. 569−75.
  143. Yu J.N., Fahey F.H., Gage H.D. et al. Intermodality, retrospective image registration in the thorax.// J. Nucl. Med.-1995.-V.36(12).-P.2333−8.
  144. Zimmer L.A., McCook Π’., Meltzer C. et al. Combined positron emission tomography/computed tomography imaging of recurrent thyroid cancer. // Otolaryngol. Head. Neck. Surg. 2003.-V. 128(2).-P. 178−84.
Π—Π°ΠΏΠΎΠ»Π½ΠΈΡ‚ΡŒ Ρ„ΠΎΡ€ΠΌΡƒ Ρ‚Π΅ΠΊΡƒΡ‰Π΅ΠΉ Ρ€Π°Π±ΠΎΡ‚ΠΎΠΉ