Π Π°Π·ΡΠ°Π±ΠΎΡΠΊΠ° ΠΌΠ΅ΡΠΎΠ΄ΠΎΠ² ΡΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΡ Π»ΡΡΠ΅Π²ΡΡ ΠΌΡΠ»ΡΡΠΈΠΌΠΎΠ΄Π°Π»ΡΠ½ΡΡ ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ ΠΈ ΠΈΡ ΠΏΡΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡ Π² ΠΊΠ»ΠΈΠ½ΠΈΠΊΠ΅
ΠΠΈΡΡΠ΅ΡΡΠ°ΡΠΈΡ
ΠΡΠ°ΠΊΡΠΈΡΠ΅ΡΠΊΠ°Ρ Π·Π½Π°ΡΠΈΠΌΠΎΡΡΡ ΡΠ°Π±ΠΎΡΡ. ΠΡΠ°ΠΊΡΠΈΡΠ΅ΡΠΊΠ°Ρ Π·Π½Π°ΡΠΈΠΌΠΎΡΡΡ ΡΠ°Π±ΠΎΡΡ Π·Π°ΠΊΠ»ΡΡΠ°Π΅ΡΡΡ Π² ΠΎΡΠ½ΠΎΡΠΈΡΠ΅Π»ΡΠ½ΠΎΠΉ ΠΏΡΠΎΡΡΠΎΡΠ΅ ΠΏΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½Π½ΠΎΠ³ΠΎ ΠΌΠ΅ΡΠΎΠ΄Π° ΡΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΡ ΠΌΡΠ»ΡΡΠΈΠΌΠΎΠ΄Π°Π»ΡΠ½ΡΡ ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ, Π½Π΅ ΡΡΠ΅Π±ΡΡΡΠ΅Π³ΠΎ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΡ ΡΠ»ΠΎΠΆΠ½ΠΎΠ³ΠΎ ΠΏΡΠΎΠ³ΡΠ°ΠΌΠΌΠ½ΠΎΠ³ΠΎ ΠΈ Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡΠ΅Π»ΡΠ½ΠΎΠ³ΠΎ ΡΠ΅Ρ Π½ΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΎΠ±Π΅ΡΠΏΠ΅ΡΠ΅Π½ΠΈΡ. Π‘ΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ ΡΠ°Π·Π»ΠΈΡΠ½ΡΡ ΠΌΠ΅ΡΠΎΠ΄ΠΎΠ² Π²ΠΈΠ·ΡΠ°Π»ΠΈΠ·Π°ΡΠΈΠΈ (ΠΠ Π’, ΠΠ‘ΠΠ’, ΠΠΠ’) Π΄Π°Π΅Ρ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΎΠ΄Π½ΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ ΠΏΠΎΠ»ΡΡΠΈΡΡ ΠΈΠ½ΡΠΎΡΠΌΠ°ΡΠΈΡ… Π§ΠΈΡΠ°ΡΡ Π΅ΡΡ >
- Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅
- ΠΡΠ΄Π΅ΡΠΆΠΊΠ°
- ΠΠΈΡΠ΅ΡΠ°ΡΡΡΠ°
- ΠΡΡΠ³ΠΈΠ΅ ΡΠ°Π±ΠΎΡΡ
- ΠΠΎΠΌΠΎΡΡ Π² Π½Π°ΠΏΠΈΡΠ°Π½ΠΈΠΈ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅
- Π‘ΠΏΠΈΡΠΎΠΊ ΡΠΎΠΊΡΠ°ΡΠ΅Π½ΠΈΠΉ
- ΠΠΠΠΠ 1. ΠΠΠΠΠ ΠΠΠ’ΠΠ ΠΠ’Π£Π Π«
- 1. 1. ΠΠ΅ΡΠΎΠ΄ΠΎΠ»ΠΎΠ³ΠΈΡΠ΅ΡΠΊΠΈΠ΅ Π°ΡΠΏΠ΅ΠΊΡΡ ΡΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΡ 9 ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ
- 1. 2. Π‘ΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ ΠΌΡΠ»ΡΡΠΈΠΌΠΎΠ΄Π°Π»ΡΠ½ΡΡ Π»ΡΡΠ΅Π²ΡΡ 17 ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ ΡΠ°Π·Π»ΠΈΡΠ½ΡΡ Π°Π½Π°ΡΠΎΠΌΠΈΡΠ΅ΡΠΊΠΈΡ ΠΎΠ±Π»Π°ΡΡΠ΅ΠΉ Π² ΠΊΠ»ΠΈΠ½ΠΈΡΠ΅ΡΠΊΠΎΠΉ ΠΏΡΠ°ΠΊΡΠΈΠΊΠ΅
- ΠΠΠΠΠ 2. ΠΠΠ©ΠΠ― Π₯ΠΠ ΠΠΠ’ΠΠ ΠΠ‘Π’ΠΠΠ ΠΠΠ’ΠΠ ΠΠΠΠ Π 26 ΠΠΠ’ΠΠΠ« ΠΠ‘Π‘ΠΠΠΠΠΠΠΠΠ―
- 2. 1. ΠΠΊΡΠΏΠ΅ΡΠΈΠΌΠ΅Π½ΡΠ°Π»ΡΠ½ΡΠ΅ ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΡ
- 2. 2. ΠΠ΅ΡΠΎΠ΄ΠΈΠΊΠΈ ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΡ
- 2. 3. ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΏΠ°ΡΠΈΠ΅Π½ΡΠΎΠ² Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ 41 ΡΡΠ΅ΡΠ΅ΠΎΡΠ°ΠΊΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ Π°Π΄Π°ΠΏΡΠ΅ΡΠ°
- 2. 4. ΠΠ΅ΡΠΎΠ΄ΠΈΠΊΠ° ΡΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΡ ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ ΡΠ°Π·Π»ΠΈΡΠ½ΡΡ 42 Π°Π½Π°ΡΠΎΠΌΠΈΡΠ΅ΡΠΊΠΈΡ ΠΎΠ±Π»Π°ΡΡΠ΅ΠΉ
- 2. 5. Π‘ΡΠ°ΡΠΈΡΡΠΈΡΠ΅ΡΠΊΠΈΠΉ Π°Π½Π°Π»ΠΈΠ· Π΄Π°Π½Π½ΡΡ
- ΠΠΠΠΠ 3. Π ΠΠΠ£ΠΠ¬Π’ΠΠ’Π« ΠΠΠ‘ΠΠΠ ΠΠΠΠΠ’ΠΠΠ¬ΠΠ«Π₯ ΠΠ‘Π‘ΠΠΠΠΠΠΠΠΠ
- ΠΠΠΠΠ 4. Π ΠΠΠ£ΠΠ¬Π’ΠΠ’Π« ΠΠΠΠΠΠ§ΠΠ‘ΠΠΠ₯ ΠΠ‘Π‘ΠΠΠΠΠΠΠΠΠ
- 4. 1. ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΡ Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ 62 ΡΡΠ΅ΡΠ΅ΠΎΡΠ°ΠΊΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ Π°Π΄Π°ΠΏΡΠ΅ΡΠ°
- 4. 2. ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΡ Π³ΠΎΠ»ΠΎΠ²Π½ΠΎΠ³ΠΎ ΠΌΠΎΠ·Π³Π° Π±Π΅Π· ΠΏΡΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡ 69 ΡΡΠ΅ΡΠ΅ΠΎΡΠ°ΠΊΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ Π°Π΄Π°ΠΏΡΠ΅ΡΠ°
- 4. 3. Π‘ΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ ΠΎΡΠ³Π°Π½ΠΎΠ² Π³ΡΡΠ΄Π½ΠΎΠΉ ΠΏΠΎΠ»ΠΎΡΡΠΈ
- 4. 4. Π‘ΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ ΠΌΡΠ»ΡΡΠΈΠΌΠΎΠ΄Π°Π»ΡΠ½ΡΡ ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ 83 Π±ΡΡΡΠ½ΠΎΠΉ ΠΏΠΎΠ»ΠΎΡΡΠΈ ΠΈ Π·Π°Π±ΡΡΡΠΈΠ½Π½ΠΎΠ³ΠΎ ΠΏΡΠΎΡΡΡΠ°Π½ΡΡΠ²Π°
- 4. 5. Π‘ΠΎΠ²ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ ΠΌΡΠ»ΡΡΠΈΠΌΠΎΠ΄Π°Π»ΡΠ½ΡΡ ΠΈΠ·ΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΠΉ 90 ΠΎΠ±Π»Π°ΡΡΠΈ ΠΌΠ°Π»ΠΎΠ³ΠΎ ΡΠ°Π·Π°
Π‘ΠΏΠΈΡΠΎΠΊ Π»ΠΈΡΠ΅ΡΠ°ΡΡΡΡ
- Antoch G- Freudenberg LS- Egelhof T, et al. Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans. // J Nucl. Med. 2002.- V.43(10).- P.1339−42.
- Antoch G- Freudenberg LS- Stattaus J- et al. Whole-body positron emission tomography-CT: optimized CT using oral and IV contrast materials. //Am. J. Roentgenol. 2002.-V.179(6).-P. 1555−60
- Antoch G- Stattaus J- Nemat AT et al. Non-small cell lung cancer: dual-modality PET/CT in preoperative staging. //Radiology -2003- 229(2): 526−33.
- Antoch G- Vogt FM- Freudenberg LS et al. Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology. //JAMA -2003.-V. 290(24).- P, 3199−206.
- Arun KS, Huang TS, Blostein SD. Least-squares fitting of two 3-D point sets. //IEEE Trans Pattern Anal Mach Intell 1987.-V.9.- P. 698 700.
- Bai C- Kinahan PE- Brasse D, et al. An analytic study of the effects of attenuation on tumor detection in whole-body PET oncology imaging.//J.Nucl.Med.-2003.-V.44(11).-P. 1855−61.
- Barillot C. Surface and volume rendering techniques to display 3-D data, an overview of basic priples shows advances in display techniques. //IEEE Engineering in Medicine and Biology -1993,-V. 12(1).-P. 111−119.8.
- Barnden L., Kwiatek R., Lau Y., et al. Validation of fully automaticbrain SPET to MR co-registration // Eur. J. Nucl. Med. Mol. Imaging. -2000.-V. 27.- P. 147−154.
- Barra V., Boire J.V. A general framework for the fusion of anatomical and functional medical images. (Part 1.) // Neuroimage 2001.- V. 13. -P. 410−424.
- Barra V., Boire J.V. A general framework for the fusion of anatomical and functional medical images. (Part 2.) // Neuroimage 2001. — V. 13.1. P. 495−515.
- Bar-Shalom R., Yefremov N., Guralnik L. et al. Clinical performance of PET/CT in evaluation of cancer: additional value for diagnostic imaging and patient management. // J. Nucl. Med. 2003. — V. 44(8). — P. 12 001 209.
- Bartenstein P., Griinwald F., Kuwert T. et al. Clinical applications of single photon emission tomography in neuromedicine. // Nuklearmedizin. 2000.-V. 39.-P. 180−95.
- Benyounes H., Smith F.W., Campbell N.T.S. et al. Superimposition of PET images using 18 F-fluorodeoxyglucose with magnetic resonance images in patients with pancreatic carcinoma. // Nucl. Med. Commun. -1995.-V. 16.-P. 575−580.
- Beyer Π’., Townsend D.W., Brun T. A combined PET/CT scanner for clinical oncology. // J. Nucl. Med. 2000. — V.41(8). — P. 1369−1379.
- Beyer Π’., Watson C.C., Meltzer C.C. et al. The biograph: A Premium Dual-Modality PET/CT Tomograph for Clinical Oncology. // Electromedica. -2001.-V. 69. -P. 120−126.
- Beyer Π’., Townsend D.W., Blodgett T.M. Dual-modality PET/CT tomography for clinical oncology// J. Nucl. Med. -2002.- V.46(l).- P. 24−34.
- Beyer Π’., Yau Y.Y., Kaepplinger S. PET/CT tomography using a new PET detector material for ultra-fast imaging in clinical oncology. //Electromedica. 2002. -V.70. — P. 151−156.
- Beyer Π’., Antoch G., Blodgett T. et al. Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology.// Eur. J. Nucl. Med. Mol. Imaging 2003.- V.30(4).-P. 588−96.
- Bomanji J.B., Costa D. C, Ell P.J.Clinical role of positron emission tomography in oncology. // Lancet Oncol. 2001.- V. 2(3).- P. 157−64.
- Bookstein F.L., Green W.D. Edge information at landmarks in medical images. //Proceedings of the Second Conference on Visualization in Biomedical Computing, Chapel Hill, NC.- 1992.- P. 242−258.
- Boussion N., Cinotti L., Barra V. et al. Extraction of epileptogenic foci from PET and SPECT images by fuzzy modeling and data fusion. // Neuroimage—2003.—V.19(3).-P.645−654.
- Bristow R.E., del Carmen M.G., Pannu H.K. et al. Clinically occult recurrent ovarian cancer: patient selection for secondary cytoreductive surgery using combined PET/CT. // Gynecol. Oncol. -2003.- V.90(3).-P.519−528.
- Chajari M., Lacroix J., Peny A.M. et al. Gallium-67 scintigraphy in lymphoma: is there a benefit of image fusion with computed tomography? // Eur. J. Nucl. Med. Mol. Imaging — 2002. — V. 29(3).1. P. 380−387.
- Charron M., Beyer Π’., Bohnen N.N. et al. Image analysis in patients with cancer studied with a combined PET and CT scanner. //Clin. Nucl. Med.-2000.-V.25(l 1).P.-905−910.
- Chen C.T. Radiologic Image Registration: Old Skills and New Tools // Acad. Radiol. 2003.- V.10.-P.239−241.
- Cohade C., Osman M., Leal J., Wahl R.L. Direct comparison of (18)F-FDG PET and PET/CT in patients with colorectal carcinoma.// J Nucl Med.-2003 .-V.44(11).-P. 1797−803
- Cohade C., Osman M., Nakamoto Y., et al. Initial experience with oral contrast in PET/CT: phantom and clinical studies. //J Nucl Med -12 003 .-44(3).-412−416
- Cohade C., Wahl R.L. Applications of positron emission tomography/computed tomography image fusion in clinical positron emission tomography-clinical use, interpretation methods, diagnostic improvements.//Semin.Nucl.Med.-2003. — V.33(3).- P. 228−237.
- Duncan J. S: Imaging and epilepsy. //Brain 1997.- V. 120.- P. 339−337.
- Delbeke D., Martin W.H. Positron emission tomography imaging in oncology.//Radio.l Clin. North. Am. -2001.- V. 39(5).- P. 883−917.
- Dufner F., Schifbauer H., Breit S. et al. Relevance of Image Fusion for Target Point Determination in Functional Neurosurgery. // Acta Neurochir (Wien). 2002. — Vol. 144.-P.445 -451.
- Egidi M., Rampini P., Locatelli M. et al. Visualization of the subthalamic nucleus: a multiple sequential image fusion (MuSIF) technique for direct stereotaxic localisation and postoperative control.// Neurol. Sci.-2002.-V.23 .-Suppl.2.-P.71 -2
- Eggert D. W., Lorusso A., Fisher R. B, Estimating 3-D rigid body transformations: a comparison for four major algorithms // Mach. Vision Appl. 1997.-V.9.- P.272−290.
- Emri M., Esik O., Repa I., Marian Π’., Tron L. Image fusion of different tomographic methods (PET/CT/MRI) effectively contribute to therapy planning. // Orv. Hetil. 1997.- V.138(46).- P. 2919−24
- Eubank W.B., Mankoff D.A., Schmiedl U.P., Winter T.C.Fisher Imaging of oncologic patients: benefit of combined CT and FDG PET in the diagnosis of malignancy.//AJR 1998.- V.171.- P. l 103 -1110.
- Faist M., Xie J., Kurz D. Effect of bilateral subthalamic nucleus stimulation on gait in Parkinson’s disease. // Brain 2001.- V.124 (Pt. 8) P. 1590−600.
- Forster G.J., Laumann C., Nickel O., et al. SPET/CT image coregistration in the abdomen with a simple and cost-effective tool. // Eur. J. Nucl. Med. Mol. Imaging.-2003.-V.30(l).-P.32−39.
- Fitzpatrick J.M., West J.B., Maurer C.R.J. Predicting error in rigid-body point-based registration. //IEEE Trans. Med. Imaging 1998.-V.17.-P.694−702.
- Galloway R.L., Maciunas R.J., Edwards C.A. Interactive image guided neurosurgery. /ΠΠΠΠ Trans Biomedical Engineering 1992.- V.39(12).-P.l 126−1231.
- Garlick P.B., Marsden P.K., Cave A.C., et al. PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat hearts. // NMR.Biomed.-1997.-V.10(3).-P.138−142.
- Gerig G., Martin J., Kikinis R., et al. Unsupervised tissue type segmentation of 3-D dual MR head data.// Image and Vision Computing. 1992. — V. 10(6). — P. 349−360.
- Gingold E.L., Hasegawa B.H. Systematic bias in basis material decomposition applied to quantitative dual-energy x-ray imaging. // Med.Phys.-1992.-V. 19(1).-P.25−33.
- Goerres G.W., Burger C., Schwitter M.R. et al.- PET/CT of the abdomen: optimizing the patient breathing pattern. // Eur. Radiol. -2003.- V.13(4).- P. 734−739.
- Goshtasby A. Registration of images with geometric distortions //IEEE Trans. Geosci. Remote Sensing. 1988.- V. 26.- P.60−64.
- Goodall C. Procrustes methods in the statistical analysis of shape // J. R. Statist. Soc. Π .1991.- V.53.- P.285−339.
- Graham J.D., Warrington A.P., Gill S.S., Brada M. A noninvasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging. // Radiother. Oncology. 1991. — V.2. — P. 60−2.
- Griffin L. The intrinsic geometry of the cerebral cortex. Journal of Theoretical Biology.- 1994.-V. 166(3).- P. 261−273.
- Grova C., Jannin P., Biraben A. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy. // Phys.Med.Biol.-2003.-V.48(24).-P.4023−4043.
- Grzeszczuk R., Tan K.K., Levin D.N. et. al. Retrospective fusion of radiographic and MR data for localization of subdural electrodes. // J. Comput. Assist.Tomogr.-1992.-V. 16(5).-P.764−73.
- Guralnik L., Werbin N., Iosilevsky G., Israel O. The new technology of combined transmission and emission tomography in evaluation of endocrine neoplasms. //J. Nucl. Med. 2001.- V.42.- P.998 -1004.
- Hamilton R.J., Blend M.J., Pelizzari C.A., et al. Using vascular structure for CT-SPECT registration in the pelvis. // J. Nucl. Med. -1999.- V.40(2).- P. 347−51.
- Hasegawa B.H., Stebler Π., Rutt B.K. A prototype high-purity germanium detector system with fast photon-counting circuitry for medical imaging. //Med. Phys. 1991. -V. 18(5). — P. 900−909.
- Hasegawa B.H., Wong K.H., Iwata K., et al. Dual-modality imaging of cancer with SPECT/CT.// Technol. Cancer. Res. Treat. -2002.- V. l (6). -P.449−58.
- Hasegawa B.H., Iwata K., Wong K.H., et al. Dual-modality imaging of function and physiology. //Acad. Radiol.- 2002.- V.9.- P.1305−1321.
- Hawkes D. J. The accuracy of 3D image registration using point landmarks. // Tech. Rep. RS94/1, UMDS, London, 1995.
- Hawkes D.J. Algorithms for radiological image registration and their clinical application. // J. Anat. 1998.- V.193.- P. 347−361.
- Hill D.L.G. Combination of 3D medical images from multiple modalities. //University of London, 1993.
- Hill D. L. G, Hawkes D. J., Gleeson M. J., et al. Accurate frameless registration of MR and CT images of the head: Applications in surgery and radiotherapy planning. // Radiology 1994.-Y. 191.- P.447−454.
- Hill D. L. G., Maurer Jr .C. R et al. Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm.// J. Comput. Assist. Tomogr 1998.- V22.- P.317−323.
- Hill D.L.G., Batchelor P.G., Holden M., Hawkes D.J. Medical image registration. //Phys. Med. Biol. 2001.- V.46.-R1-R45.
- Hum M.A., Mardia K.V., Hainsworth T.J., et al. Bayesian fused classification of medical images. // IEEE Trans. Medical Imaging. -1996.-V. 15.-P. 259−302.
- Jiang H., Robb R.A., Holton K.S. A new approach to 3-D registration of multimodality images by surface matching. //Proceedings of the Second Conference on Visualization in Biomedical Computing, Chapel Hill, NC.-1992.-P. 196−213.
- Julow J., Major Π’., Valalik I. The Application of Image Fusion in Stereotactic Brachytherapy of Brain Tumours// Acta Neurochir (Wien). -2000.- V.142: P.1253−1258.
- Imth G. Graphics applied to medical image registration/. //IEEE Comput. Graph. Appl., March 1991.- V. 11.- P.20−29.
- Kamel E.M., Burger C., Buck A. Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner. // Eur. Radiol,-2003.-V.13(4).-P.724−728.
- Kaiboriboon K., Lowe V.J., Chantarujikapong S.I. Hogan RE The usefulness of subtraction ictal SPECT coregistered to MRI in single-and dual-headed SPECT cameras in partial epilepsy. // Epilepsia -2002.- V.43(4).-P. 408−414.
- Kashiwagi Π’., Yutani Π., Fukuchi M. et al. Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT. // Ann. Nucl. Med. 2002.- V.16(4).- P.255−61.
- Kawaharada Y., Itou A. Registration of chest PET and CT images-fusion technique using the PET/Tr image by the respiration compensation. // Kaku Igaku Japanese Journal of Nuclear Medicine] - 2003.-V.40(l).-P.l-9.
- Kinahan P.E., Hasegawa B.H., Beyer T. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. // Semin. Nucl. Med. 2003. — V. 33(3). — P. 166−79.
- Kluetz P.G., Meltzer C.C., Villemagne M.G. et al. Combined PET/CT imaging in oncology: impact on patient managment. //Clin. Positron. Imaging. 2000.- V. 3. — P. 223 — 230.
- Lang T.F., Hasegawa B.H., Liew S.C. et al. Description of a prototype emission-transmission computed tomography imaging system.//J.Nucl.Med.-l 992.-V.33(l 0).-P. 1881−7.
- Liew S.C., Hasegawa B.H. Noise, resolution, and sensitivity considerations in the design of a single-slice emission-transmission computed tomographic system. // Med. Phys. — 1991. -V.18(5). — P. 1002−15.
- Levin D.N., Pelizzari C.A., Chen G.T.Y. et al. Retrospective geometric correlation of MR, CT, and PET images. // Radiology 1988.- V.169.-P. 817−823.
- Loats H. CT and SPECT image registration and fusion for spatial localization of metastatic processes using radiolabeled monoclonals. //
- J. Nucl. Med.-1993.- V.34(3 Suppl).- P.562−566.
- Maintz J.B.A., Viergever M.A. A survey of medical image registration. //Med. Image. Anal. 1998.-V. 2.-P.1−36.
- Maurer C.R., Mc Croy J.J., Fitzpatrick J.M. Estimation of accuracy in localizing externally attached markers in multimodal volume head images. //In: Loew MH, ed. Proc SPIE V.1898. Medical Imaging 1993: Image Processing 1993.- V.12.-P.43−54.
- Maurer C.R., Fitzpatrick J.M., A review of medical image registration. //In Interactive Image-Guided Neurosurgery (R. J. Maciunas, ed.), P. 17−44, Park Ridge, IL: American Association of Neurological Surgeons, 1993.
- Mandava V. R., Fitzpatrick J. M., Maurer Jr. C. R. et al. Registration of multimodal volume head images via attached markers. // Medical Imaging VI: Image Processing 1992. Vol. Proc. SPIE 1652, P. 271 282.
- Myers R .The application of PET-MR image registration in the brain. // Br.J.Radiol.-2002.-V.75.-Spec.-No.-S.31−35.
- Nakamoto Y., Osman M., Cohade C. et al. PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images. // J. Nucl. Med. 2002.- V.43(9).- P. 113 743.
- Nakamoto Y., Chin B.B., Kraitchman D.L. et al. Effects of nonionic intravenous contrast agents at PET/CT imaging: phantom and canine studies.//Radiology-2003.-V.227(3).-P.817−824.
- Nakamoto Y., Tatsumi M., Cohade C. et al. Accuracy of image fusion of normal upper abdominal organs visualized with PET/CT. //Eur. J. Nucl.Med.Mol.Imaging-2003.-V.30(4).-P.597−602.
- Nishioka Π’., Shiga Π’., Shirato H. et al. Image fusion between 18FDG-PET and MRI/CT for radiotherapy planning of oropharyngeal and nasopharyngeal carcinomas. //Int. J. Radiat. Oncol. Biol. Phys. --2002,-V.53(4).- P.1051−1057.
- Minotti A.J., Shah L., Keller K. Positron emission tomography/computed tomography fusion imaging in brown adipose tissue. // Clin. Nucl. Med.- 2004.-29(1).- P. 5−11.
- Oberg K. Neuroendocrine gastrintestinal tumors — a condensed overview of diagnosis and treatment.//Ann. Oncol. 1999.V.10.-P.53 -58.
- Olivier A., Germano I.M., Cukiert A., Peters T. Frameless stereotaxy for surgery of the epilepsies: preliminary experience. Technical note. // J.Neurosurg.-1994.-V.81 (4).-P.629−633.
- Osman M.M., Cohade C., Nakamoto Y., Wahl R.L. Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT. Eur. J. Nucl. Med. Mol. Imaging — 2003.-V.30(4).-P.603−6.
- Osman M.M., Cohade C., Nakamoto Y., et al.- Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients. // J. Nucl. Med. 2003.- V.44(2).- P.240−3.
- Pannu H.K., Bristow R.E., Cohade C. et al. PET-CT in recurrent ovarian cancer: initial observations. // Radiographics — 2004.1. V.24(l).- P.209−223.
- Patel P.V., Cohade C., Chin B.B. PET-CT localizes previously undetectable metastatic lesions in recurrent fallopian tube carcinoma. // Gynecol. Oncol. -2002.- V.87(3).- P.323−6.
- Patton J.A., Debelke D., Sandler M.P. Image fusion using an integrated, dual-head coincidence camera with x-ray tube-based attenuation maps.//J. Nucl. Med. 2000.- V.41.- P. 1364 -1368.
- Pelizzari C.A. Image processing in stereotactic planning: volume visualization and image registration. // Med. Dosim.-1998.- 23(3).- P. 137−145.
- Pelizzari C. A., Chen G. T. Y., Spelbring D. R. et al. Accurate three-dimensional registration of CT, PET, and/or MR images of the brain, // J. Comput. Assist. Tomogr. 1989.- V. 13.- P. 20−26.
- Pernus F., Stiehl H.S., Viergever M.A., eds. Special issue on biomedical image registration. // Image Vis. Comput. 2001.- V.19.-P.l-96.
- Peters A.R., Muller S.H., de Munck J.C., van Herk M. The accuracy of image registration for the brain and the nasopharynx using external anatomical landmarks. // Phys. Med. Biol. 2000.- V.45(8).- P.2403−2416.
- Pietrzyk U., Herholz K., Heiss W.D. Three-dimensional alignment of functional and morphological tomograms. // J. Comput. Assist. Tomogr. 1990 — V. 14(1). — P. 51 -59.
- Pietrzyk U., Herholz K, Schuster A. et al. Clinical applications of registration and fusion of multimodality brain images from PET,
- SPECT, CT, and MRI. // Eur. J. Radiol. -1996.- V.21(3).-P.174−182.
- Pfannenberg A.C., Eschmann S.M., Horger M. et al. Benefit of anatomical-functional image fusion in the diagnostic work-up of neuroendocrine neoplasms. //Eur. J. Nucl. Med. Mol. Imaging. -2003.-V.30(6).- P.835−43.
- Pfluger Π’., Vollmar C., Wismuller A. et al. Quantitative comparison of automatic and interactive methods for MRI-SPECT image registration of the brain based on 3-dimensional calculation of error. // J. Nucl. Med. -2000.- V.41(l 1).-P. 1823−9.
- Rampini P.M., Locatelli M., Alimehmeti R. et al. Multiple sequential image-fusion and direct MRI localisation of the subthalamic nucleus for deep brain stimulation. // J. Neurosurg. Sci.-2003.- V.47(l).-P.33−39.
- Robb R.A. A software system for interactive and quantitative analysis of biomedical images. In: Hohne KH, Fuchs H, Pizer SM: 3D Imaging in Medicine, NATO ASI Series 1990.- V. F 60.- P.333−361.
- Rueckert D., Sonoda L., Hayes C., Hill D.L.G., Leach M., Hawkes D.J. Non-rigid registration using freeform deformations: appli-cation to breast MR images. //IEEE Trans. Med. Imaging. 1999.- V.18.-P.712−721.
- Ryan M.J., Erickson R.K., Levin D.N. et al. Frameless stereotaxy with real-time tracking of patient head movement and retrospective patient-image registration. // J. Neurosurg. 1996.- V.85(2).- P.287−292.
- Sannazzari G.L., Ragona R., Ruo Redda M.G. et al. CT-MRI image fusion for delineation of volumes in three-dimensional conformalradiation therapy in the treatment of localized prostate cancer. // Br. J. Radiol.-2002.- V.75(895).- P.603−607.
- Schellingerhout D., Lev M.H., Bagga R.J. et al. Coregistration of head CT comparison studies: assessment of clinical utility. // Acad. Radiol. -2003, — V.10.- P.242—248.
- Schoder H., Erdi Y.E., Larson S.M., Yeung H.W. PET/CT: a new imaging technology in nuclear medicine.// Eur. J. Nucl. Med. Mo. l Imaging 2003.- V.30(10).- P. 1419−1437.
- Servois V., Chauveinc L., Π.1., Khoury C. Et al. CT and MR image fusion using two different methods after prostate brachytherapy: impact on post-implant dosimetric assessment Cancer Radiother. 2003-.-7(1).- P.9−16.
- Shao Y., Cherry S.R., Farahani K. et al. Simultaneous PET and MR imaging. // Phys. Med. Biol.- 1997. V. 42(10). — P. 1965−70.
- Shreve P.D. Adding structure to function (invited commentary). //J. Nucl. Med. -2000.-V. 41.-P. 1380−1382.
- Studholme Π‘., Hill D. L. G., Hawkes D. J., Automated 3D registration of MR and CT images of the head, // Med. Image Anal. 1996 — V.I.-P. 163−175.
- Studholme C., Hill D. L. G., Hawkes D. J. Automated 3D registration of MR and PET brain images by multi-resolution optimisation of voxel similarity measures. // Med. Phys.- 1997.- V. 24.- P.25−35.
- Stytz M.R., Frieder G., Frieder O. Three-dimensional medical imaging: algorithms and computer systems.//ACM Computer Surveys 1991.-V.23(4).-P.421−499.
- Sure U., Benes L. U. Image fusion for skull base neuronavigation-technical note //Neurol. Med.Chir. (Tokyo) 2002.- V.42(10).-P. 45 862.
- Suri J.S. Two dimensional fast MR brain segmentation using a region-based level set approach. International Journal of Engin-eering in Medicine and Biology.-2001.- P. 14−15.
- Suri J.S., Setarehdan S.K., Singh S. Advanced Algorithmic Approaches to Medical Image Segmentation: State-of-the-Art Applications in Cardiology, Neurology, Mammography and Pathology. Springer, London, 2001.
- Tan K.K., Grzeszczuk R., Levin D.N. A frameless stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note. //J.Neurosurg.-1993.-V.79(2).- P.296−303.
- Tang H.R., Da Silva A.J., Matthay K.K. et al. Neuroblastoma imaging using a combined CT scanner-scintillation camera and 131I-MIBG.// J. Nucl. Med. 2001. — V. 42(2). — P. 237−47.
- Tatsumi M., Cohade Π‘., Nakamoto Y., Wahl R.L. Fluorodeoxyglucose uptake in the aortic wall at PET/CT: possible finding for active atherosclerosis.//Radiolog.-2003.-V.229(3).-P.831−7.
- Thomas C.T., Meyer C.R., Koeppe R.A. et al. A positron-emitting internal marker for identification of normal tissue by positron emission tomography: phantom studies and validation in patients. // Mol. Imaging. Biol.-2003.-V.5(2).- P.79−85.
- Toet A., Franken E. M. Perceptual evaluation of different image fusion schemes. // 2003. Displays.- V. 24, — no.l.- P. 25−37.
- Townsend D.W., Cherry S.R. Combining anatomy and function: the path to true image fusion. //Eur. Radiol. 2001.- V. 11.- P. 1968−1974.
- Townsend D.W. A combined PET/CT scanner: the choices. // J Nucl. Med.-2001.- V.42(3).- P.533−534.
- Townsend D.W., Beyer T. A combined PET/CT scanner: the path to true image fusion. // Br. J. Radiol. 2002.- V.75 Spec No: S24−30.
- Townsend D.W., Beyer Π’., Blodgett T.M. PET/CT scanners: a hardware approach to image fusion.//Semin. Nucl. Med. — 2003.-V.33(3).-193−204.
- Thurfjell L., Pagani M. Andersson J.L.R. et al. Registration of neuroimaging data Implementation and clinical applications //J.Neuroim—2000.-V.10.-P.39−46.
- Turkington T.G., Hoffman J.M., Jaszczak R.J. Accuracy of surface fit registration for PET and MR brain images using full and incomplete brain surfaces. //J. Comput. Assist. Tomog. 1995.-V. 19(1).- P. 117
- Turkington T.G., Jaszczak R.J., Pelizzari C.A., Harris C.C., MacFall J.R., Hoffman J.M., Coleman R.E. Accuracy of registration of PET, SPECT and MR images of a brain phantom. //J. Nucl. Med. 1993.-V.34.- P. 1587−1594.
- Van den Elsen P.A., Pol E.J.D., Viergever M.A. Medical image matching: a review with classification. // IEEE Trans. Eng. Biol.-1993.-V. 12.-P.26−39.
- Van Heertum R.L., Drocea C., Ichise M. et al. Single photon emission CT and positron emission tomography in the evaluation of neurologic disease. // Radiol. Clin. North. Am. -2001.-V.39(5).- P. 1007−33.
- Visvikis D., Costa D.C., Croasdale I. et al. CT-based attenuation correction in the calculation of semi-quantitative indices of 18FJFDG uptake in PET. // Eur. J. Nucl. Med. Mol. Imaging. -2003.-V.30(3).-344−353.
- Wahl R.L., Quint L.E., Cieslak R.D., Aisen A.M., et al. «Anatometabolic» tumour imaging: fusion of FDG PET with CT or MR to localize foci of increased activity.//J. Nucl. Med. 1993.- V.34.-P.l 190−1197.
- Wahl R.L. Progress in nuclear medicine imaging of cancers. // Prim. Care. -1998.- V.25(2).-341−346.
- Wahl R.L. Anatomolecular imaging with 2-deoxy-2-18 °F.fluoro-D-glucose: bench to outpatient center. // Mol. Imaging. Biol. -2003.-V.5(2).-P.49−56.
- Wang M. Y., Fitzpatrick J. M., Maurer C. R. Jr., Maciunas R. J, Anautomatic technique for localizing externally attached markers in MR and CT volume images of the head. // Medical. Imaging.- 1994 Image Processing — V. Proc. SPIE 2167.- P. 214−224.
- Wang Z., Bovik A.C. A universal image quality index. // IEEE Signal Processing Letters. 2002.- V. 9.- β.3.- P. 81−84.
- West J.B., Fitzpatrick J.M., Toms S.A. et al. Fiducial point placement and the accuracy of point-based, rigid body registration. //Neurosurgery -2001 .-V.48(4).-P.810−6-discussion.-P.816−817.
- West J.B., Fitzpatrick J.M., Wang M.Y. et al. Comparison and evaluation of retrospective intermodality brain image registration techniques. // J. Comput. Assist. Tomogr.- 1998 .- V.21.- P. 554−566.
- Wong J.C.H., Studholme C., Hawkes D.J., Maisey M.N. Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study. //Eur J. Nucl. Med. -1997.- V.24.- P.642−650.
- Woods R.P., Mazziotta J.C., Cherry S.R., MRI-PET registration with automated algorithm, // J. Comput. Assist. Tomogr. 1993. — V.17.- P. 536−546.
- Wu X., Brown JK., Kalki K., Hasegawa B.H. Characterization and correction of pulse pile-up in simultaneous emission-transmissioncomputed tomography. // Med Phys. 1996. -V. 23(4). — P. 569−75.
- Yu J.N., Fahey F.H., Gage H.D. et al. Intermodality, retrospective image registration in the thorax.// J. Nucl. Med.-1995.-V.36(12).-P.2333−8.
- Zimmer L.A., McCook Π., Meltzer C. et al. Combined positron emission tomography/computed tomography imaging of recurrent thyroid cancer. // Otolaryngol. Head. Neck. Surg. 2003.-V. 128(2).-P. 178−84.